Manufacturing of fiber Bragg grating smart steel strand finished cables

Purpose This study aims to develop a sensing-integrated finished cable by embedding fiber Bragg grating (FBG) strain sensors in a steel strand and to verify sensor survivability plus anchorage/load-bearing performance under static tension. Design/methodology/approach Five FBG sensors were embedded in a longitudinal groove of the strand’s central wire. Three finished-cable specimens were fabricated using an anchor cup and cold-cast filler. Static tensile tests were conducted following GBT14370-2015, and strains were monitored in the anchorage zone and the middle free section to evaluate calibration performance, monitoring range, anchorage efficiency and ultimate capacity. Findings All sensors survived loading (100% survival). Calibration showed strong linearity with a correlation coefficient exceeding 99.657%. Effective monitoring was maintained up to 80% of ultimate capacity; data anomalies at 95% load were excluded, and the monitoring range was concluded as 0%–90%. The finished cable achieved an average ultimate capacity of 821 kN versus a theoretical 790 kN, with anchorage efficiency coefficients of 1.013, 1.069 and 1.077 (>0.95). Anchorage-zone strain presented three stages (<80% gradual rise; 80–90% reduced growth due to slip; >90% sharp rise with cold-cast cracking). Research limitations/implications Only three short specimens and static tests were used. Future work should assess fatigue, corrosion/temperature effects and full-scale field deployment. Results support the feasibility of embedded-FBG monitoring without degrading capacity. Practical implications The cable can be installed like a conventional prestressing tendon while providing real-time force/strain monitoring, including within the anchorage zone, reducing labor-intensive field measurements. Social implications More reliable cable monitoring supports early warning for bridges and cable-supported buildings, reducing the risk of sudden failures and service interruptions. Originality/value The work couples multi-point embedded FBG sensing with a finished multi-strand cable and experimentally validates both sensing reliability and anchorage/ultimate capacity in one program.

Authors

Institutions

Publication Details

Journal
Sensor Review
Published
2026-03-03
DOI
https://doi.org/10.1108/sr-12-2025-1099
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Manufacturing of fiber Bragg grating smart steel strand finished cables

Mingdong Li, Wanxu ZHU, Haowei Xu, Congshi Lao et al.
Sensor Review
Advanced Fiber Optic Sensors
article

Manufacturing of fiber Bragg grating smart steel strand finished cables

Mingdong Li, Wanxu ZHU, Haowei Xu, Congshi Lao, Daojun Feng
article en

Abstract

Purpose This study aims to develop a sensing-integrated finished cable by embedding fiber Bragg grating (FBG) strain sensors in a steel strand and to verify sensor survivability plus anchorage/load-bearing performance under static tension. Design/methodology/approach Five FBG sensors were embedded in a longitudinal groove of the strand’s central wire. Three finished-cable specimens were fabricated using an anchor cup and cold-cast filler. Static tensile tests were conducted following GBT14370-2015, and strains were monitored in the anchorage zone and the middle free section to evaluate calibration performance, monitoring range, anchorage efficiency and ultimate capacity. Findings All sensors survived loading (100% survival). Calibration showed strong linearity with a correlation coefficient exceeding 99.657%. Effective monitoring was maintained up to 80% of ultimate capacity; data anomalies at 95% load were excluded, and the monitoring range was concluded as 0%–90%. The finished cable achieved an average ultimate capacity of 821 kN versus a theoretical 790 kN, with anchorage efficiency coefficients of 1.013, 1.069 and 1.077 (>0.95). Anchorage-zone strain presented three stages (<80% gradual rise; 80–90% reduced growth due to slip; >90% sharp rise with cold-cast cracking). Research limitations/implications Only three short specimens and static tests were used. Future work should assess fatigue, corrosion/temperature effects and full-scale field deployment. Results support the feasibility of embedded-FBG monitoring without degrading capacity. Practical implications The cable can be installed like a conventional prestressing tendon while providing real-time force/strain monitoring, including within the anchorage zone, reducing labor-intensive field measurements. Social implications More reliable cable monitoring supports early warning for bridges and cable-supported buildings, reducing the risk of sudden failures and service interruptions. Originality/value The work couples multi-point embedded FBG sensing with a finished multi-strand cable and experimentally validates both sensing reliability and anchorage/ultimate capacity in one program.

Sensor Review
Guilin University of Aerospace Technology (CN), Guilin University of Technology (CN), Yunnan Investment Group (China) (CN), Guilin University of Electronic Technology (CN)
Openalex Percentile: Top 38%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.