Electrochemical Sensor of Ciprofloxacin on Screen-Printed Electrode Modified with Boron-Doped Diamond Nanoparticles and Nickel Oxide Nanoparticles Biosynthesized Using Spatholobus littoralis Hassk. Root Extract

Ciprofloxacin (CIP) is an antibiotic that is widely used in humans and animals. However, the compound has been detected in animal-derived products and the environment due to its extensive use, causing serious concern for public health and environmental safety. The issue raises the urgent need to develop innovative techniques to monitor CIP. Therefore, this study aims to develop a simple and sensitive CIP sensor called the boron-doped diamond nanoparticle-modified screen-printed electrode (BDD NPs/SPE) and the nickel oxide nanoparticle-modified BDD NPs/SPE (NiO NPs/BDD NPs/SPE). NiO NPs were synthesized via green synthesis using <i>Spatholobus littoralis Hassk.</i> root extract as the reducing agent. The formation and characteristics of NiO NPs were then confirmed through a UV-Vis spectrophotometer, XRD, PSA, FT-IR, and XPS. The successful modification of SPE was confirmed through SEM-EDX, followed by measurements using square-wave voltammetry. The results showed that the modified SPE could detect CIP over a concentration range of 0.1-100 µM and produced a low detection limit of 0.109 µM for BDD NPs/SPE and 0.054 µM for NiO NPs/BDD NPs/SPE. The proposed method was successfully applied to the determination of CIP in commercial tablets, milk, and human urine, with a satisfactory % recovery from 95 to 100%. The current study successfully developed a simple yet highly sensitive sensor that enabled robust, reliable, and efficient detection of CIP, showing its strong potential for practical applications.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-03-03
DOI
https://doi.org/10.3390/bios16030148
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Sensor of Ciprofloxacin on Screen-Printed Electrode Modified with Boron-Doped Diamond Nanoparticles and Nickel Oxide Nanoparticles Biosynthesized Using Spatholobus littoralis Hassk. Root Extract

Widiastuti Setyaningsih, Ilma Amalina, Wan Jeffrey Basirun, Tahta Amrillah et al.
Biosensors
Electrochemical sensors and biosensors
article

Electrochemical Sensor of Ciprofloxacin on Screen-Printed Electrode Modified with Boron-Doped Diamond Nanoparticles and Nickel Oxide Nanoparticles Biosynthesized Using Spatholobus littoralis Hassk. Root Extract

Widiastuti Setyaningsih, Ilma Amalina, Wan Jeffrey Basirun, Tahta Amrillah, Mai Tomisaki, Nurul Mutmainah Diah Oktaviani, Mirza Ardella Saputra, Laurencia Gabrielle Sutanto, Qonita Kurnia Anjani, Yasuaki Einaga, Prastika Krisma Jiwanti
article en

Abstract

Ciprofloxacin (CIP) is an antibiotic that is widely used in humans and animals. However, the compound has been detected in animal-derived products and the environment due to its extensive use, causing serious concern for public health and environmental safety. The issue raises the urgent need to develop innovative techniques to monitor CIP. Therefore, this study aims to develop a simple and sensitive CIP sensor called the boron-doped diamond nanoparticle-modified screen-printed electrode (BDD NPs/SPE) and the nickel oxide nanoparticle-modified BDD NPs/SPE (NiO NPs/BDD NPs/SPE). NiO NPs were synthesized via green synthesis using <i>Spatholobus littoralis Hassk.</i> root extract as the reducing agent. The formation and characteristics of NiO NPs were then confirmed through a UV-Vis spectrophotometer, XRD, PSA, FT-IR, and XPS. The successful modification of SPE was confirmed through SEM-EDX, followed by measurements using square-wave voltammetry. The results showed that the modified SPE could detect CIP over a concentration range of 0.1-100 µM and produced a low detection limit of 0.109 µM for BDD NPs/SPE and 0.054 µM for NiO NPs/BDD NPs/SPE. The proposed method was successfully applied to the determination of CIP in commercial tablets, milk, and human urine, with a satisfactory % recovery from 95 to 100%. The current study successfully developed a simple yet highly sensitive sensor that enabled robust, reliable, and efficient detection of CIP, showing its strong potential for practical applications.

BiosensorsVol. 16(3)
Queen's University Belfast (GB), Kyushu University (JP), Universitas Gadjah Mada (ID), Keio University (JP), Universitas Airlangga (ID), University of Malaya (MY), Telkom University (ID)
Openalex Percentile: Top 38%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.