Effect of Thickness on Thermo-Hydraulic Performance of a DPHE with Twisted Perforated Tapes: A Numerical Study

While twisted tape inserts are widely used for heat transfer enhancement, the specific impact of tape thickness remains under-explored. This study provides a systematic numerical investigation into the thermo-hydraulic performance of a double-pipe heat exchanger equipped with twisted perforated tape (TPT) inserts of varying thicknesses (1, 1.5, and 2 mm). Using a validated 3D SST k−ω model across Re = 1000–12,000, the research establishes a mechanistic distinction between flow regimes. The results indicate that the 2 mm TPT yields the highest enhancement, achieving a 78.6% increase in the average Nusselt number (Nuavg) and a 67.8% improvement in the overall heat transfer coefficient at Re = 12,000. Quantitative analysis of secondary flow intensity and turbulence kinetic energy confirms a transition from geometry-induced swirl at low Re to turbulence-driven shear at high Re. Despite a pressure drop penalty of up to 3.26 times the plain tube, the thermal performance factor remained above unity for all cases, peaking at 1.17 at Re ≈ 4000. These findings establish tape thickness as a first-order design variable for optimizing high-performance thermal systems.

Authors

Institutions

Publication Details

Journal
Thermo
Published
2026-03-03
DOI
https://doi.org/10.3390/thermo6010018
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Thickness on Thermo-Hydraulic Performance of a DPHE with Twisted Perforated Tapes: A Numerical Study

Aizat Abas, Ashraf Emad Almerane
Thermo
Heat Transfer and Optimization
article

Effect of Thickness on Thermo-Hydraulic Performance of a DPHE with Twisted Perforated Tapes: A Numerical Study

Aizat Abas, Ashraf Emad Almerane
article en

Abstract

While twisted tape inserts are widely used for heat transfer enhancement, the specific impact of tape thickness remains under-explored. This study provides a systematic numerical investigation into the thermo-hydraulic performance of a double-pipe heat exchanger equipped with twisted perforated tape (TPT) inserts of varying thicknesses (1, 1.5, and 2 mm). Using a validated 3D SST k−ω model across Re = 1000–12,000, the research establishes a mechanistic distinction between flow regimes. The results indicate that the 2 mm TPT yields the highest enhancement, achieving a 78.6% increase in the average Nusselt number (Nuavg) and a 67.8% improvement in the overall heat transfer coefficient at Re = 12,000. Quantitative analysis of secondary flow intensity and turbulence kinetic energy confirms a transition from geometry-induced swirl at low Re to turbulence-driven shear at high Re. Despite a pressure drop penalty of up to 3.26 times the plain tube, the thermal performance factor remained above unity for all cases, peaking at 1.17 at Re ≈ 4000. These findings establish tape thickness as a first-order design variable for optimizing high-performance thermal systems.

ThermoVol. 6(1)
Universiti Sains Malaysia (MY), Northern Technical University (IQ)
Affordable and clean energy
Openalex Percentile: Top 38%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.