Planar Microwave Sensor for the Characterization of Milk

This paper presents the development and analysis of a planar microwave sensor designed for detecting adulteration in milk by evaluating the purity of milk in a water-based solution. The sensor comprises a pair of complementary split-ring resonators (CSRRs) fabricated on an FR4 substrate, measuring 30 mm × 50 mm × 1.6 mm, with a dielectric constant of 4.4 and a loss tangent of 0.022. The device’s performance was assessed using a vector network analyzer (VNA) by varying the ratio of full-cream milk to water in a 50 mL solution, starting from 60% and increasing in 10% increments up to 100%. Measurements focused on return loss (RL) at resonant frequency 1.5425 GHz, which exhibited minimal frequency shifts but significant variations in RL magnitude with changing milk concentration (M). To establish a mathematical relationship between RL and M, we segmented the data into two ranges—60% to 80% and 80% to 100% milk concentrations—and applied second-order polynomial regression for each segment. The quadratic equations derived from this regression allowed us to express M in terms of RL. Verification of this method was conducted using arbitrary samples of milk concentrations: 61%, 62%, 72%, 88%, 93%, and 95%. Discrepancies between different quadratic solutions for the same RL values were resolved by normalizing the return losses against pure water and comparing the resulting normalized values with those from known concentrations. This comparison allowed for the accurate selection of the appropriate quadratic equation based on the closest match. Our normalization approach revealed distinct patterns correlating RL magnitudes, enabling us to select the appropriate quadratic equation segment based on minimal discrepancies. The analysis confirmed that by excluding negative and complex solutions and solutions which are beyond the stipulated range of the curve segment, the accuracy of the sensor in determining milk concentration exceeded 83.5%. This study demonstrates the potential of the proposed microwave sensor in ensuring milk quality by effectively quantifying milk purity.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-03-03
DOI
https://doi.org/10.3390/electronics15051059
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Planar Microwave Sensor for the Characterization of Milk

H.K. Lee, N. Effendy, Nurhamidar Rahman, Foo Wei Lee et al.
Electronics
Microwave and Dielectric Measurement Techniques
article

Planar Microwave Sensor for the Characterization of Milk

H.K. Lee, N. Effendy, Nurhamidar Rahman, Foo Wei Lee, Kim Ho Yeap, Pek Lan Toh, Siu Hong Loh, Kim Hoe Tshai, Ming Hui Tan, Kok Weng Tan, Yong Jun Tan
article en

Abstract

This paper presents the development and analysis of a planar microwave sensor designed for detecting adulteration in milk by evaluating the purity of milk in a water-based solution. The sensor comprises a pair of complementary split-ring resonators (CSRRs) fabricated on an FR4 substrate, measuring 30 mm × 50 mm × 1.6 mm, with a dielectric constant of 4.4 and a loss tangent of 0.022. The device’s performance was assessed using a vector network analyzer (VNA) by varying the ratio of full-cream milk to water in a 50 mL solution, starting from 60% and increasing in 10% increments up to 100%. Measurements focused on return loss (RL) at resonant frequency 1.5425 GHz, which exhibited minimal frequency shifts but significant variations in RL magnitude with changing milk concentration (M). To establish a mathematical relationship between RL and M, we segmented the data into two ranges—60% to 80% and 80% to 100% milk concentrations—and applied second-order polynomial regression for each segment. The quadratic equations derived from this regression allowed us to express M in terms of RL. Verification of this method was conducted using arbitrary samples of milk concentrations: 61%, 62%, 72%, 88%, 93%, and 95%. Discrepancies between different quadratic solutions for the same RL values were resolved by normalizing the return losses against pure water and comparing the resulting normalized values with those from known concentrations. This comparison allowed for the accurate selection of the appropriate quadratic equation based on the closest match. Our normalization approach revealed distinct patterns correlating RL magnitudes, enabling us to select the appropriate quadratic equation segment based on minimal discrepancies. The analysis confirmed that by excluding negative and complex solutions and solutions which are beyond the stipulated range of the curve segment, the accuracy of the sensor in determining milk concentration exceeded 83.5%. This study demonstrates the potential of the proposed microwave sensor in ensuring milk quality by effectively quantifying milk purity.

ElectronicsVol. 15(5)
Taylor's University (MY), Universiti Tunku Abdul Rahman (MY)
Clean water and sanitation
Openalex Percentile: Top 39%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.