In-incubator continuous and endpoint monitoring of angiogenesis using a chip-sized holographic microscope

Continuous monitoring of cell-to-cell interactions and multicellular network dynamics is essential for in situ biosensing, drug screening and cell-based assays. However, conventional live-cell imaging relies on benchtop optical microscopes placed outside the incubator, which limits throughput and makes long-term, minimally perturbative monitoring difficult. Here, we present a chip-sized, lensless digital holographic microscope (CSM) designed for compact, scalable, low-cost and in-incubator imaging of live-cell assays. The CSM combines a CMOS sensor and a micro-LED array in an inline holographic configuration, enabling wide-field, label-free imaging directly inside a standard CO<sub>2</sub> incubator. The CSM was validated using a Vascular Endothelial Growth Factor (VEGF)-induced tube formation assay with primary human umbilical vein endothelial cells (HUVECs). Quantitative network metrics (total tube length, number of junctions and meshes, and mean mesh area) are extracted from numerically reconstructed images and are shown to capture dose-dependent effects of VEGF. At 24 h, the CSM resolved significant increases in tube length and junction count at 20-40 ng/mL VEGF-165, followed by a marked regression at 50 ng/mL, and achieved a morphological detection limit of 1383 μm<sup>2</sup> in mesh area with a corresponding morphological dynamic range of 1643. Time-lapse imaging every 30 min further resolves the full temporal evolution of tube formation and regression, revealing kinetic differences that are not accessible from endpoint measurements alone. These results establish the CSM as a versatile platform for quantitative, in-incubator monitoring of angiogenesis assays, bridging continuous imaging and endpoint read-outs.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2026-03-03
DOI
https://doi.org/10.1016/j.bios.2026.118579
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-incubator continuous and endpoint monitoring of angiogenesis using a chip-sized holographic microscope

Sergio Ruiz Moreno, Anna Alabart Vilà, Á. Diéguez, Sofía Moncada-Madrazo et al.
Biosensors and Bioelectronics
Digital Holography and Microscopy
article

In-incubator continuous and endpoint monitoring of angiogenesis using a chip-sized holographic microscope

Sergio Ruiz Moreno, Anna Alabart Vilà, Á. Diéguez, Sofía Moncada-Madrazo, Oriol Caravaca, Javier Ramon-Azcon, Joan Canals, Natalia Castro
article en

Abstract

Continuous monitoring of cell-to-cell interactions and multicellular network dynamics is essential for in situ biosensing, drug screening and cell-based assays. However, conventional live-cell imaging relies on benchtop optical microscopes placed outside the incubator, which limits throughput and makes long-term, minimally perturbative monitoring difficult. Here, we present a chip-sized, lensless digital holographic microscope (CSM) designed for compact, scalable, low-cost and in-incubator imaging of live-cell assays. The CSM combines a CMOS sensor and a micro-LED array in an inline holographic configuration, enabling wide-field, label-free imaging directly inside a standard CO<sub>2</sub> incubator. The CSM was validated using a Vascular Endothelial Growth Factor (VEGF)-induced tube formation assay with primary human umbilical vein endothelial cells (HUVECs). Quantitative network metrics (total tube length, number of junctions and meshes, and mean mesh area) are extracted from numerically reconstructed images and are shown to capture dose-dependent effects of VEGF. At 24 h, the CSM resolved significant increases in tube length and junction count at 20-40 ng/mL VEGF-165, followed by a marked regression at 50 ng/mL, and achieved a morphological detection limit of 1383 μm<sup>2</sup> in mesh area with a corresponding morphological dynamic range of 1643. Time-lapse imaging every 30 min further resolves the full temporal evolution of tube formation and regression, revealing kinetic differences that are not accessible from endpoint measurements alone. These results establish the CSM as a versatile platform for quantitative, in-incubator monitoring of angiogenesis assays, bridging continuous imaging and endpoint read-outs.

Biosensors and BioelectronicsVol. 303
Institute for Bioengineering of Catalonia (ES), Institut de Nanociència i Nanotecnologia de la Universitat de Barcelona, Universitat de Barcelona (ES)
Openalex Percentile: Top 37%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.