MHz-rate Beam Position and Pulse Energy Measurements with a Diamond Sensor at European XFEL

The diagnostics of the X-ray beam properties has a critical importance at the European X-ray Free Electron Laser facility. Besides existing diagnostic components, utilization of a diamond sensor was proposed to achieve radiation-hard, non-invasive beam position and pulse energy measurements for hard X-rays1. In particular, at very hard X-rays diamond-based sensors become a useful complement to gas-based devices which lose sensitivity due to significantly reduced gas cross-sections. A semiconductor detector based on a single crystal chemical vapor deposition (scCVD) diamond with a duo-lateral configuration for position sensitivity was proposed and successfully used at the synchrotron environment2. The first results obtained with a similar diamond sensor placed in the photon tunnel of European XFEL demonstrates pulse-resolved X-ray beam position within less than 1% uncertainty at 2.25 MHz3. The measurements presented in this work were performed with diamond sensors having similar properties and structure but with a different resistive coating. Here pulse-resolved beam intensity and position measurements performed at the Material Imaging and Dynamics (MID)4 instrument at the European XFEL are presented.

Authors

Publication Details

Journal
European XFEL Publication Database
Published
2024-11-14
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MHz-rate Beam Position and Pulse Energy Measurements with a Diamond Sensor at European XFEL

Alexey Zozulya, Angel Rodríguez-Fernández, Jörg Hallmann, Jan Grünert et al.
European XFEL Publication Database
Diamond and Carbon-based Materials Research
article

MHz-rate Beam Position and Pulse Energy Measurements with a Diamond Sensor at European XFEL

Alexey Zozulya, Angel Rodríguez-Fernández, Jörg Hallmann, Jan Grünert, Ulrike Boesenberg, Wonhyuk Jo, Tuba Çonka Yildiz, Wolfgang Freund, Roman Shayduk, M. Schreck, Jia Liu, Anders Madsen
article en

Abstract

The diagnostics of the X-ray beam properties has a critical importance at the European X-ray Free Electron Laser facility. Besides existing diagnostic components, utilization of a diamond sensor was proposed to achieve radiation-hard, non-invasive beam position and pulse energy measurements for hard X-rays1. In particular, at very hard X-rays diamond-based sensors become a useful complement to gas-based devices which lose sensitivity due to significantly reduced gas cross-sections. A semiconductor detector based on a single crystal chemical vapor deposition (scCVD) diamond with a duo-lateral configuration for position sensitivity was proposed and successfully used at the synchrotron environment2. The first results obtained with a similar diamond sensor placed in the photon tunnel of European XFEL demonstrates pulse-resolved X-ray beam position within less than 1% uncertainty at 2.25 MHz3. The measurements presented in this work were performed with diamond sensors having similar properties and structure but with a different resistive coating. Here pulse-resolved beam intensity and position measurements performed at the Material Imaging and Dynamics (MID)4 instrument at the European XFEL are presented.

European XFEL Publication Database
Affordable and clean energy
Openalex Percentile: Top 66%
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.