Environmental Evaluation of VOC Emissions in CIPP Rehabilitation: Comparative Analysis of Resin Types and Curing Techniques

Aging underground pipeline infrastructure across the United States, including systems used for potable water supply, wastewater collection, and stormwater conveyance, has exceeded its intended service life, emphasizing the need for replacement or rehabilitation to maintain reliable service to communities. Among available trenchless technologies, cured-in-place pipe (CIPP) is widely applied because it minimizes surface disruption and is well-suited for use in densely populated areas. Despite these advantages, environmental concerns remain regarding the release of total volatile organic compounds (VOCs) during CIPP installation and curing. This study evaluates total VOC emissions from CIPP liners under field conditions. Air samples were collected at six installation sites across the United States before, during, and after installation and curing to quantify key VOC species. Multiple sampling methods were employed, including photoionization detectors (PIDs), Summa canisters, and personal worker sampling. The measured compounds included styrene, cumene, acetophenone, hexane, toluene, and ethanol. Measured concentrations were compared with occupational exposure limits established by the U.S. Environmental Protection Agency (USEPA), the National Institute for Occupational Safety and Health (NIOSH), and the Occupational Safety and Health Administration (OSHA). The results indicate that styrene was the dominant compound within active CIPP work zones, with peak concentrations reaching 25.5 ppm during curing. In contrast, VOC concentrations decreased substantially within five feet downwind of the work zone. Overall, the findings suggest that potential public exposure risks are limited, while workers directly involved in CIPP operations may experience elevated short-term exposures during installation and curing activities.

Authors

Institutions

Publication Details

Journal
Pollutants
Published
2026-03-02
DOI
https://doi.org/10.3390/pollutants6010014
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmental Evaluation of VOC Emissions in CIPP Rehabilitation: Comparative Analysis of Resin Types and Curing Techniques

Rasoul Adnan Abbas, Shima Zare, Sevda Jannatdoust, Mohammad Najafi
Pollutants
Geotechnical Engineering and Underground Structures
article

Environmental Evaluation of VOC Emissions in CIPP Rehabilitation: Comparative Analysis of Resin Types and Curing Techniques

Rasoul Adnan Abbas, Shima Zare, Sevda Jannatdoust, Mohammad Najafi
article en

Abstract

Aging underground pipeline infrastructure across the United States, including systems used for potable water supply, wastewater collection, and stormwater conveyance, has exceeded its intended service life, emphasizing the need for replacement or rehabilitation to maintain reliable service to communities. Among available trenchless technologies, cured-in-place pipe (CIPP) is widely applied because it minimizes surface disruption and is well-suited for use in densely populated areas. Despite these advantages, environmental concerns remain regarding the release of total volatile organic compounds (VOCs) during CIPP installation and curing. This study evaluates total VOC emissions from CIPP liners under field conditions. Air samples were collected at six installation sites across the United States before, during, and after installation and curing to quantify key VOC species. Multiple sampling methods were employed, including photoionization detectors (PIDs), Summa canisters, and personal worker sampling. The measured compounds included styrene, cumene, acetophenone, hexane, toluene, and ethanol. Measured concentrations were compared with occupational exposure limits established by the U.S. Environmental Protection Agency (USEPA), the National Institute for Occupational Safety and Health (NIOSH), and the Occupational Safety and Health Administration (OSHA). The results indicate that styrene was the dominant compound within active CIPP work zones, with peak concentrations reaching 25.5 ppm during curing. In contrast, VOC concentrations decreased substantially within five feet downwind of the work zone. Overall, the findings suggest that potential public exposure risks are limited, while workers directly involved in CIPP operations may experience elevated short-term exposures during installation and curing activities.

PollutantsVol. 6(1)
The University of Texas at Arlington (US)
Clean water and sanitation
Openalex Percentile: Top 38%
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Environmental Evaluation of VOC Emissions in CIPP Rehabilitation: Comparative Analysis of Resin Types and Curing Techniques — Rasoul Adnan Abbas, Shima Zare, et al. · Pollutants (2026) | TGRS Research Map | TGRS