Study on shear behavior of head enlarged anchorage connector used in LEM-filled CFS shear wall to floor connection

Lightweight EPS material (LEM)-filled cold-formed steel (CFS) shear wall structures may exhibit dis-continuities in shear transfer for their vertical lateral force-resisting elements. To investigate the shear performance of the head enlarged anchorage (HEA) connector used in LEM-filled CFS shear wall-to-floor connections, shear push-out tests were conducted on five specimens. The effects of embedment depth, LEM strength, and enlarged end area on the failure modes, load-displacement relationships, and shear capacity of the connectors were analyzed. Experimental results demonstrate that the enlarged anchorage effectively enhanced the shear performance of the connectors. Numerical simulations were subsequently carried out on the shear performance of the HEA connectors, and the simulation results were calibrated and validated against experimental data, confirming the reliability of the modeling approach. Further analysis based on stress distribution and contact stress provided additional insight into the structural behavior of HEA connectors. Finally, a parametric study was conducted to evaluate the influence of four key factors including the thickness of LEM and CFS, the strength of CFS, and the anchorage location of the enlarged end. The results revealed that the first three parameters considerably affect shear capacity, whereas the anchorage location of the enlarged end exhibited a very limited effect on shear performance. These findings of this study provide a theoretical foundation for the design and application of floor connection methods in LEM-filled CFS shear wall structures.

Authors

Institutions

Publication Details

Journal
Structures
Published
2026-03-02
DOI
https://doi.org/10.1016/j.istruc.2026.111494
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on shear behavior of head enlarged anchorage connector used in LEM-filled CFS shear wall to floor connection

Wanqian Wang, Yibo Yang, Jingfeng Wang, Lei Guo et al.
Structures
Structural Load-Bearing Analysis
article

Study on shear behavior of head enlarged anchorage connector used in LEM-filled CFS shear wall to floor connection

Wanqian Wang, Yibo Yang, Jingfeng Wang, Lei Guo, Yixuan Sun
article en

Abstract

Lightweight EPS material (LEM)-filled cold-formed steel (CFS) shear wall structures may exhibit dis-continuities in shear transfer for their vertical lateral force-resisting elements. To investigate the shear performance of the head enlarged anchorage (HEA) connector used in LEM-filled CFS shear wall-to-floor connections, shear push-out tests were conducted on five specimens. The effects of embedment depth, LEM strength, and enlarged end area on the failure modes, load-displacement relationships, and shear capacity of the connectors were analyzed. Experimental results demonstrate that the enlarged anchorage effectively enhanced the shear performance of the connectors. Numerical simulations were subsequently carried out on the shear performance of the HEA connectors, and the simulation results were calibrated and validated against experimental data, confirming the reliability of the modeling approach. Further analysis based on stress distribution and contact stress provided additional insight into the structural behavior of HEA connectors. Finally, a parametric study was conducted to evaluate the influence of four key factors including the thickness of LEM and CFS, the strength of CFS, and the anchorage location of the enlarged end. The results revealed that the first three parameters considerably affect shear capacity, whereas the anchorage location of the enlarged end exhibited a very limited effect on shear performance. These findings of this study provide a theoretical foundation for the design and application of floor connection methods in LEM-filled CFS shear wall structures.

StructuresVol. 86
Hefei University of Technology (CN)
Sustainable cities and communities
Openalex Percentile: Top 38%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on shear behavior of head enlarged anchorage connector used in LEM-filled CFS shear wall to floor connection — Wanqian Wang, Yibo Yang, et al. · Structures (2026) | TGRS Research Map | TGRS