Ahmed Glaucoma Valve as a Risk Factor for Penetrating Keratoplasty Failure

Background and objectives: Penetrating keratoplasty is a surgical procedure with a history spanning over a century. The objective is to identify the incidence and potential risk factor of graft failure after performing penetrating keratoplasty in eyes with Ahmed valve tube. Methods: This retrospective study conducted on 24 patients whom penetrating keratoplasty and glaucoma shunt surgery have been performed for them from February 2017 to December 2022 at North eye center/ Erbil city. The follow up was obtained for determining the risk factors associated with keratoplasty failure. Results: Half of the patients with glaucoma drainage devices have a successful penetrating keratoplasty surgery. Age was not a risk factor for penetrating keratoplasty failure, relative risk (RR)=0.85, CI=0.38-1.88, P=0.682). Also, the following factors were not a risk for keratoplasty failure; sex (RR=1,CI=0.45-2.23, P=1), sequence of surgery of Ahmed valve prior to penetrating keratoplasty (RR=0.57,CI=0.20-1.53, P=0.206), eye laterality (RR=1.23,95%CI=0.47-3.25, P=653), aphakia (RR=4.0,CI=0.12-136.95, P=0.215) and pseudophakia (RR=5.71,CI=0.52-62.66 P=0.154), history of vitreoretinal surgery is the risk factor for penetrating keratoplasty failure (RR=3.4,95%CI=1.63-7.10,P=0.002), chronic diseases (RR=0.79,95%CI=0.34-1.86,P=0.615) and intraocular pressure>21 mmHg (RR=1.214,95%CI=0.54-2.75,P=0.653) are also risk factors for decreasing success of penetrating keratoplasty. Conclusion: In our study, Ahmed valve is a risk factor for failure of pentrating keratoplasty surgery which is 50%. Age, gender, Ahmed valve prior to penetrating keratoplasty, lens status and operated eye were not a risk factor in pentrating keratoplasty failure in those who underwent glaucoma drainage device. Whereas, vitreoretinal surgery, chronic diseases and intraocular pressure were observed as risk factors in penetrating keratoplasty failure.

Authors

Institutions

Publication Details

Journal
Advanced medical journal
Published
2026-03-03
DOI
https://doi.org/10.56056/amj.2026.448
Primary Topic
Corneal Surgery and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ahmed Glaucoma Valve as a Risk Factor for Penetrating Keratoplasty Failure

Karwan Bakhtyar Mohammed, Kawa Khalil Ahmad
Advanced medical journal
Corneal Surgery and Treatments
article

Ahmed Glaucoma Valve as a Risk Factor for Penetrating Keratoplasty Failure

Karwan Bakhtyar Mohammed, Kawa Khalil Ahmad
article en

Abstract

Background and objectives: Penetrating keratoplasty is a surgical procedure with a history spanning over a century. The objective is to identify the incidence and potential risk factor of graft failure after performing penetrating keratoplasty in eyes with Ahmed valve tube. Methods: This retrospective study conducted on 24 patients whom penetrating keratoplasty and glaucoma shunt surgery have been performed for them from February 2017 to December 2022 at North eye center/ Erbil city. The follow up was obtained for determining the risk factors associated with keratoplasty failure. Results: Half of the patients with glaucoma drainage devices have a successful penetrating keratoplasty surgery. Age was not a risk factor for penetrating keratoplasty failure, relative risk (RR)=0.85, CI=0.38-1.88, P=0.682). Also, the following factors were not a risk for keratoplasty failure; sex (RR=1,CI=0.45-2.23, P=1), sequence of surgery of Ahmed valve prior to penetrating keratoplasty (RR=0.57,CI=0.20-1.53, P=0.206), eye laterality (RR=1.23,95%CI=0.47-3.25, P=653), aphakia (RR=4.0,CI=0.12-136.95, P=0.215) and pseudophakia (RR=5.71,CI=0.52-62.66 P=0.154), history of vitreoretinal surgery is the risk factor for penetrating keratoplasty failure (RR=3.4,95%CI=1.63-7.10,P=0.002), chronic diseases (RR=0.79,95%CI=0.34-1.86,P=0.615) and intraocular pressure>21 mmHg (RR=1.214,95%CI=0.54-2.75,P=0.653) are also risk factors for decreasing success of penetrating keratoplasty. Conclusion: In our study, Ahmed valve is a risk factor for failure of pentrating keratoplasty surgery which is 50%. Age, gender, Ahmed valve prior to penetrating keratoplasty, lens status and operated eye were not a risk factor in pentrating keratoplasty failure in those who underwent glaucoma drainage device. Whereas, vitreoretinal surgery, chronic diseases and intraocular pressure were observed as risk factors in penetrating keratoplasty failure.

Advanced medical journalVol. 11(1)
Hawler Medical University (IQ), Lebanese French University (IQ)
Good health and well-being
Openalex Percentile: Top 38%
Corneal Surgery and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ahmed Glaucoma Valve as a Risk Factor for Penetrating Keratoplasty Failure — Karwan Bakhtyar Mohammed, Kawa Khalil Ahmad · Advanced medical journal (2026) | TGRS Research Map | TGRS