Breaking Local Symmetry with Axial Cl to Steer Nonradical Polymerization of Phenol over a Co Single-Atom Catalyst

Single-atom catalysts (SACs) with asymmetrically engineered coordination environments are promising for advancing peroxymonosulfate (PMS)-based advanced oxidation. Yet, achieving precise control over the electronic and geometric structure of the metal center to direct reaction pathways beyond mineralization remains a substantial challenge. To address this challenge, we reported a planar-axial dual-regulation strategy to fabricate a cobalt SAC featuring a tailored Co–N3 plane and an axial chlorine ligand (denoted as Cl–Co–N3). At a rate constant of 0.208 min–1, which exceeded most reported heterogeneous catalysts, this asymmetric site enabled ultrarapid (>98% within 30 min) phenol removal by optimizing the Co electronic state. The system performed robustly across a wide pH range and resisted common water-matrix interfering substances. Integrated experimental probes and theoretical simulations revealed that the reaction proceeds predominantly by means of a nonradical electron-transfer mechanism. The axial Cl coordination modulated the d-band center of Co, enhanced charge transfer capacity, and strengthened PMS adsorption/activation, leading to the generation of a high-potential surface-activated PMS* complex. This complex drives efficient one-electron oxidation of phenol to generate phenoxyl radicals, which subsequently undergo oxidative coupling and chain-growth polymerization, transforming pollutants into separable macromolecular products on the catalyst surface. Consequently, this unique nonmineralization pathway achieved an exceptionally high electron utilization efficiency of 181.6%, drastically reducing oxidant consumption. Our work offers a molecular-level design principle for engineering efficient SACs toward oxidant-economical, polymerization-based water decontamination.

Authors

Institutions

Publication Details

Journal
ACS ES&T Engineering
Published
2026-03-02
DOI
https://doi.org/10.1021/acsestengg.6c00041
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breaking Local Symmetry with Axial Cl to Steer Nonradical Polymerization of Phenol over a Co Single-Atom Catalyst

Wentian Zheng, Yifan Ren, Yi-Xiang Wang, Chenxin Xie et al.
ACS ES&T Engineering
Advanced oxidation water treatment
article

Breaking Local Symmetry with Axial Cl to Steer Nonradical Polymerization of Phenol over a Co Single-Atom Catalyst

Wentian Zheng, Yifan Ren, Yi-Xiang Wang, Chenxin Xie, Yanbiao Liu, Xing Li
article en

Abstract

Single-atom catalysts (SACs) with asymmetrically engineered coordination environments are promising for advancing peroxymonosulfate (PMS)-based advanced oxidation. Yet, achieving precise control over the electronic and geometric structure of the metal center to direct reaction pathways beyond mineralization remains a substantial challenge. To address this challenge, we reported a planar-axial dual-regulation strategy to fabricate a cobalt SAC featuring a tailored Co–N3 plane and an axial chlorine ligand (denoted as Cl–Co–N3). At a rate constant of 0.208 min–1, which exceeded most reported heterogeneous catalysts, this asymmetric site enabled ultrarapid (>98% within 30 min) phenol removal by optimizing the Co electronic state. The system performed robustly across a wide pH range and resisted common water-matrix interfering substances. Integrated experimental probes and theoretical simulations revealed that the reaction proceeds predominantly by means of a nonradical electron-transfer mechanism. The axial Cl coordination modulated the d-band center of Co, enhanced charge transfer capacity, and strengthened PMS adsorption/activation, leading to the generation of a high-potential surface-activated PMS* complex. This complex drives efficient one-electron oxidation of phenol to generate phenoxyl radicals, which subsequently undergo oxidative coupling and chain-growth polymerization, transforming pollutants into separable macromolecular products on the catalyst surface. Consequently, this unique nonmineralization pathway achieved an exceptionally high electron utilization efficiency of 181.6%, drastically reducing oxidant consumption. Our work offers a molecular-level design principle for engineering efficient SACs toward oxidant-economical, polymerization-based water decontamination.

ACS ES&T EngineeringVol. 6(3)
Donghua University (CN), Dalian University of Technology (CN), Tianjin Municipal Engineering Design and Research Institute (CN)
Clean water and sanitation
Openalex Percentile: Top 41%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.