Optimal design and operation of Photovoltage distributed generators and shunt compensators for the Vietnam alternative current distribution network to reduce annual energy loss

This study presents the application of two novel meta-heuristic algorithms, including the Fungal Growth Optimizer (FGO) and Animated Oat Optimization Algorithm (AOO), to optimize the placement of DGs and SCBs for power loss reduction in three alternative current distribution networks (ACDNs), including a practical ACDN with 55 nodes in Vietnam, besides the two IEEE standard ACDNs. In the study, placement of DGs and SCBs on the three grids is conducted in two phases, including the designing phase and the operational phase. In the designing phase, DGs and SCBs were optimized in their placement on the grids by the two algorithms in various scenarios with different DG configurations. The results achieved through scenarios indicate that AOO completely outperforms FGO in terms of the optimal total active power loss values (TAPL) and the stability of the outputs. Particularly, in the two scenarios conducted on the IEEE 69-node, the TAPL achieved by AOO is better than FGO, 3.65% for the first scenario and 72.28% for the second scenario. In the other two scenarios conducted on the IEEE 85-node, AOO still proves its high effectiveness over FGO by reaching the better TAPL at 6.02% in Scenario 1 and 44.88% in Scenario 2. Lastly, AOO is continuously superior to FGO in the four scenarios in the Vietnam ACDN, with 55-node by 1.04% in Scenario 1, 19.52% in Scenario 2, 7.07% in Scenario 3, and 69.60% in Scenario 4. Next in the operational phase, AOO is reapplied to optimize the power output of PVDGs and SCBs within an average day of the first month in the four quarters of the year, with load demand variation and dynamic supplied power from PVDGs in four scenarios with different settings of PVDGs and SCBs. The results clearly reveal that the operational Scenario 4 with PVDGs is configured to supply both active and reactive power to the grid, along with SCBs, which offer the best value of energy loss in the three quarters, except for the third one, where the operational Scenario 2 is the most suited for energy loss.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-03-02
DOI
https://doi.org/10.1371/journal.pone.0342402
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal design and operation of Photovoltage distributed generators and shunt compensators for the Vietnam alternative current distribution network to reduce annual energy loss

Bon Nhan Nguyen, Valeriy E. Arkhincheev, Thang Trung Nguyen, Minh Phuc Duong
PLoS ONE
Optimal Power Flow Distribution
article

Optimal design and operation of Photovoltage distributed generators and shunt compensators for the Vietnam alternative current distribution network to reduce annual energy loss

Bon Nhan Nguyen, Valeriy E. Arkhincheev, Thang Trung Nguyen, Minh Phuc Duong
article en

Abstract

This study presents the application of two novel meta-heuristic algorithms, including the Fungal Growth Optimizer (FGO) and Animated Oat Optimization Algorithm (AOO), to optimize the placement of DGs and SCBs for power loss reduction in three alternative current distribution networks (ACDNs), including a practical ACDN with 55 nodes in Vietnam, besides the two IEEE standard ACDNs. In the study, placement of DGs and SCBs on the three grids is conducted in two phases, including the designing phase and the operational phase. In the designing phase, DGs and SCBs were optimized in their placement on the grids by the two algorithms in various scenarios with different DG configurations. The results achieved through scenarios indicate that AOO completely outperforms FGO in terms of the optimal total active power loss values (TAPL) and the stability of the outputs. Particularly, in the two scenarios conducted on the IEEE 69-node, the TAPL achieved by AOO is better than FGO, 3.65% for the first scenario and 72.28% for the second scenario. In the other two scenarios conducted on the IEEE 85-node, AOO still proves its high effectiveness over FGO by reaching the better TAPL at 6.02% in Scenario 1 and 44.88% in Scenario 2. Lastly, AOO is continuously superior to FGO in the four scenarios in the Vietnam ACDN, with 55-node by 1.04% in Scenario 1, 19.52% in Scenario 2, 7.07% in Scenario 3, and 69.60% in Scenario 4. Next in the operational phase, AOO is reapplied to optimize the power output of PVDGs and SCBs within an average day of the first month in the four quarters of the year, with load demand variation and dynamic supplied power from PVDGs in four scenarios with different settings of PVDGs and SCBs. The results clearly reveal that the operational Scenario 4 with PVDGs is configured to supply both active and reactive power to the grid, along with SCBs, which offer the best value of energy loss in the three quarters, except for the third one, where the operational Scenario 2 is the most suited for energy loss.

PLoS ONEVol. 21(3)
Ton Duc Thang University (VN), Siberian State University of Telecommunications and Information Science (RU), Ho Chi Minh City University of Technology and Engineering (VN), Ho Chi Minh City University of Technology (VN)
Affordable and clean energy
Openalex Percentile: Top 40%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.