Quantification of Sonicated Implants from Patients with Osteoarticular Implant Infections

<b>Background:</b> Sonication of retrieved implants has emerged as a valuable diagnostic adjunct for Prosthetic Joint Infection (PJI), particularly in chronic infections or cases with prior antibiotic exposure. Quantitative culture of sonication fluid has been proposed to differentiate contamination from true infection; however, the diagnostic thresholds remain inconsistent across studies and may be influenced by methodological variability. <b>Objectives:</b> We aimed to evaluate bacterial counts obtained from the routine sonication of osteoarticular implants and assess their diagnostic performance across different infection types. <b>Methods:</b> A retrospective study was conducted (2011-2023) at a tertiary hospital. Implants from patients with PJI or Fracture-Related Infection (FRI), classified according to international criteria, were processed using a standardized sonication protocol, including centrifugation and inoculation onto multiple culture media. Quantitative results were expressed as CFU/mL. Bacterial counts were compared across infection types (acute PJI, chronic PJI, FRI), microbial characteristics, infection pattern, and affected joint using non-parametric tests. <b>Results:</b> A total of 457 sonicated implants were analyzed, including 316 PJI samples (26.3% acute; 73.7% chronic) and 141 FRI samples. The median bacterial count was 40,000 CFU/mL (IQR 1000-100,000). No significant differences were found between prosthetic and osteosynthesis implants. Polymicrobial infections showed significantly higher counts than monomicrobial infections (<i>p</i> < 0.005). No significant differences were observed according to Gram stain or joint site. Acute PJI tended to show higher bacterial burdens than chronic PJI, although not significantly (<i>p</i> = 0.052). <b>Conclusions:</b> Quantitative sonication yields substantial variability in bacterial loads, with higher counts in polymicrobial infections and a trend toward increased counts in acute PJI. A threshold of ≥1000 CFU/mL appeared to be clinically meaningful within our protocol. These findings support the diagnostic utility of quantitative sonication and underscore the need for protocol-specific thresholds.

Authors

Institutions

Publication Details

Journal
Antibiotics
Published
2026-03-02
DOI
https://doi.org/10.3390/antibiotics15030258
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of Sonicated Implants from Patients with Osteoarticular Implant Infections

Jaime Esteban, Álvaro Auñón, R. Parrón, J. Garcia-Cañete et al.
Antibiotics
Orthopedic Infections and Treatments
article

Quantification of Sonicated Implants from Patients with Osteoarticular Implant Infections

Jaime Esteban, Álvaro Auñón, R. Parrón, J. Garcia-Cañete, L. Salar Vidal, L. Trallero-Calvo, A. Blanco
article en

Abstract

<b>Background:</b> Sonication of retrieved implants has emerged as a valuable diagnostic adjunct for Prosthetic Joint Infection (PJI), particularly in chronic infections or cases with prior antibiotic exposure. Quantitative culture of sonication fluid has been proposed to differentiate contamination from true infection; however, the diagnostic thresholds remain inconsistent across studies and may be influenced by methodological variability. <b>Objectives:</b> We aimed to evaluate bacterial counts obtained from the routine sonication of osteoarticular implants and assess their diagnostic performance across different infection types. <b>Methods:</b> A retrospective study was conducted (2011-2023) at a tertiary hospital. Implants from patients with PJI or Fracture-Related Infection (FRI), classified according to international criteria, were processed using a standardized sonication protocol, including centrifugation and inoculation onto multiple culture media. Quantitative results were expressed as CFU/mL. Bacterial counts were compared across infection types (acute PJI, chronic PJI, FRI), microbial characteristics, infection pattern, and affected joint using non-parametric tests. <b>Results:</b> A total of 457 sonicated implants were analyzed, including 316 PJI samples (26.3% acute; 73.7% chronic) and 141 FRI samples. The median bacterial count was 40,000 CFU/mL (IQR 1000-100,000). No significant differences were found between prosthetic and osteosynthesis implants. Polymicrobial infections showed significantly higher counts than monomicrobial infections (<i>p</i> < 0.005). No significant differences were observed according to Gram stain or joint site. Acute PJI tended to show higher bacterial burdens than chronic PJI, although not significantly (<i>p</i> = 0.052). <b>Conclusions:</b> Quantitative sonication yields substantial variability in bacterial loads, with higher counts in polymicrobial infections and a trend toward increased counts in acute PJI. A threshold of ≥1000 CFU/mL appeared to be clinically meaningful within our protocol. These findings support the diagnostic utility of quantitative sonication and underscore the need for protocol-specific thresholds.

AntibioticsVol. 15(3)
Centro de Investigación Biomédica en Red (ES), Hospital Universitario Fundación Jiménez Díaz (ES), Universidad Autónoma de Madrid (ES)
Openalex Percentile: Top 37%
Orthopedic Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.