Deformation Capacity of FRP-Strengthened RC Columns with Lap Splices

Deficient lap splices in the plastic hinge regions of RC columns are common in older, seismically vulnerable buildings. Over the last two decades, numerous studies have investigated retrofit strategies for such columns, with fiber-reinforced polymer (FRP) jacketing being one of the most widely adopted. This technical note compiles an experimental database of 75 FRP-jacketed RC columns with insufficient lap splices tested under reversed cyclic loading to assess parameters that impact their deformation capacity. The database is further used to evaluate current American Concrete Institute standard provisions for lap-spliced RC columns. An updated design equation, consistent with the current American Concrete Institute standard, is proposed for determining the minimum FRP thickness to prevent lap splice failure. Alternatively, a minimum clamping coefficient is recommended to calculate the required FRP thickness.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2026-03-02
DOI
https://doi.org/10.1061/jccof2.cceng-5520
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deformation Capacity of FRP-Strengthened RC Columns with Lap Splices

John W. Wallace, Mehmet Emre Unal
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
article

Deformation Capacity of FRP-Strengthened RC Columns with Lap Splices

John W. Wallace, Mehmet Emre Unal
article en

Abstract

Deficient lap splices in the plastic hinge regions of RC columns are common in older, seismically vulnerable buildings. Over the last two decades, numerous studies have investigated retrofit strategies for such columns, with fiber-reinforced polymer (FRP) jacketing being one of the most widely adopted. This technical note compiles an experimental database of 75 FRP-jacketed RC columns with insufficient lap splices tested under reversed cyclic loading to assess parameters that impact their deformation capacity. The database is further used to evaluate current American Concrete Institute standard provisions for lap-spliced RC columns. An updated design equation, consistent with the current American Concrete Institute standard, is proposed for determining the minimum FRP thickness to prevent lap splice failure. Alternatively, a minimum clamping coefficient is recommended to calculate the required FRP thickness.

Journal of Composites for ConstructionVol. 30(3)
University of California System (US), Institute for Structural Research (PL)
Sustainable cities and communities
Openalex Percentile: Top 39%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Deformation Capacity of FRP-Strengthened RC Columns with Lap Splices — John W. Wallace, Mehmet Emre Unal · Journal of Composites for Construction (2026) | TGRS Research Map | TGRS