Determination of low glucose level using smart copper(II)oxide 2D-microelectronic sensor

Hypoglycemia is an episode associated with very low glucose levels, which can be life-threatening. While research on high glucose levels related to diabetes is common, targeted critical low glucose level detection has received less attention. This study reports copper (II) oxide (CuO) micro-electronic leaflets as a smart sensor for monitoring critical low glucose levels in neutral aqueous solutions. The sensor exhibited a limit of detection (LOD) of about 2.43 × 10 −3 mol/L (2.43 mM, 43.78 mg/dL) in KCl solution and 81.2 × 10 −6 mol/L (81.2 μM, (1.46 mg/dL) in a complex medium containing ammonium phosphate, sodium chloride and sodium acetate (pH 7.12), an important value for hypoglycemia, at an applied potential of +0.225 V and −0.05 V vs. Ag/AgCl (3 M KCl) respectively. In addition, a real-life body fluid sample was evaluated through spiking with a recovery of about 99.97%. Overall, the 2D-CuO nano-edge microstructures indicate potential for rapid and reliable glucose sensing in clinical and industrial food environments. • Uniformly self-assembled 2D-engineered CuO nano-leaflets were synthesized. • The material was characterized using optical and electrochemical techniques. • The as-synthesized material was used to sense glucose in a neutral solution. • An LOD of 2.43 × 10 −3 M equivalent to 43.78 mg/dL at 0.225 V was achieved. • The CuO nanostructure shows the potential towards detecting hypoglycemia in humans.

Authors

Institutions

Publication Details

Journal
Results in Chemistry
Published
2026-03-03
DOI
https://doi.org/10.1016/j.rechem.2026.103188
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of low glucose level using smart copper(II)oxide 2D-microelectronic sensor

Dieketseng Tsotetsi, B.M. Mothudi, Mokgaotsa Jonas Mochane, Olayemi J. Fakayode et al.
Results in Chemistry
Electrochemical sensors and biosensors
article

Determination of low glucose level using smart copper(II)oxide 2D-microelectronic sensor

Dieketseng Tsotetsi, B.M. Mothudi, Mokgaotsa Jonas Mochane, Olayemi J. Fakayode, Sisonke Sigonya, Mokhotjwa Simon Dhlamini, Busisiwe P. Pertunia, Bulelwa Ntsendana, Pauline Ncube
article en

Abstract

Hypoglycemia is an episode associated with very low glucose levels, which can be life-threatening. While research on high glucose levels related to diabetes is common, targeted critical low glucose level detection has received less attention. This study reports copper (II) oxide (CuO) micro-electronic leaflets as a smart sensor for monitoring critical low glucose levels in neutral aqueous solutions. The sensor exhibited a limit of detection (LOD) of about 2.43 × 10 −3 mol/L (2.43 mM, 43.78 mg/dL) in KCl solution and 81.2 × 10 −6 mol/L (81.2 μM, (1.46 mg/dL) in a complex medium containing ammonium phosphate, sodium chloride and sodium acetate (pH 7.12), an important value for hypoglycemia, at an applied potential of +0.225 V and −0.05 V vs. Ag/AgCl (3 M KCl) respectively. In addition, a real-life body fluid sample was evaluated through spiking with a recovery of about 99.97%. Overall, the 2D-CuO nano-edge microstructures indicate potential for rapid and reliable glucose sensing in clinical and industrial food environments. • Uniformly self-assembled 2D-engineered CuO nano-leaflets were synthesized. • The material was characterized using optical and electrochemical techniques. • The as-synthesized material was used to sense glucose in a neutral solution. • An LOD of 2.43 × 10 −3 M equivalent to 43.78 mg/dL at 0.225 V was achieved. • The CuO nanostructure shows the potential towards detecting hypoglycemia in humans.

Results in ChemistryVol. 24
University of South Africa (ZA)
Affordable and clean energy
Openalex Percentile: Top 40%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of low glucose level using smart copper(II)oxide 2D-microelectronic sensor — Dieketseng Tsotetsi, B.M. Mothudi, et al. · Results in Chemistry (2026) | TGRS Research Map | TGRS