Optimization of the Identification Algorithm Using Reference Values of Gas Chromatographic Retention Indices

The capabilities of an algorithm for comparing experimental and reference values of gas chromatographic retention indices (RIs) are discussed. This algorithm was designed to eliminate significant elements of uncertainty inherent in most modern recommendations, namely, fixed values of their permissible deviations ΔRI. The proposed algorithm is oriented toward the use of variable values of deviations ΔRI = (RIref – RIexpt). It is applicable to multicomponent mixtures in which individual components with known reference values of retention indices can be reliably identified. This makes it possible to calculate the parameters of the regression equations ΔRI = (RIref – RIexpt) = aRIexpt + b with the subsequent use of these equations to recalculate the experimental RI values into the corrected values RIcorr = RIexpt + ΔRI. For example, this algorithm allows one to use reference RI values for semistandard stationary phases containing 5% phenyl groups to identify compounds by indices determined on standard nonpolar polydimethylsiloxane stationary phases and vice versa. It is applicable to both statistically processed data (presented in the format mean value ± permissible deviation) and to the results of single determinations.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2026-03-02
DOI
https://doi.org/10.1134/s1061934825701606
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the Identification Algorithm Using Reference Values of Gas Chromatographic Retention Indices

I. G. Zenkevich
Journal of Analytical Chemistry
Analytical Chemistry and Chromatography
article

Optimization of the Identification Algorithm Using Reference Values of Gas Chromatographic Retention Indices

I. G. Zenkevich
article en

Abstract

The capabilities of an algorithm for comparing experimental and reference values of gas chromatographic retention indices (RIs) are discussed. This algorithm was designed to eliminate significant elements of uncertainty inherent in most modern recommendations, namely, fixed values of their permissible deviations ΔRI. The proposed algorithm is oriented toward the use of variable values of deviations ΔRI = (RIref – RIexpt). It is applicable to multicomponent mixtures in which individual components with known reference values of retention indices can be reliably identified. This makes it possible to calculate the parameters of the regression equations ΔRI = (RIref – RIexpt) = aRIexpt + b with the subsequent use of these equations to recalculate the experimental RI values into the corrected values RIcorr = RIexpt + ΔRI. For example, this algorithm allows one to use reference RI values for semistandard stationary phases containing 5% phenyl groups to identify compounds by indices determined on standard nonpolar polydimethylsiloxane stationary phases and vice versa. It is applicable to both statistically processed data (presented in the format mean value ± permissible deviation) and to the results of single determinations.

Journal of Analytical Chemistry
St Petersburg University (RU)
Openalex Percentile: Top 40%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.