Vulnerability Analysis of the Distribution Pole-Tower Conductor System Under Typhoon and Heavy Rainfall Disasters

A vulnerability surface modeling method based on dual intensity metrics is proposed to assess the impact of typhoons and heavy rainfall disasters on the distribution pole-tower conductor system. A three-dimensional finite-element model is developed for a typical “three-pole four-conductor” distribution line, considering the uncertainties in both load-side and structural-side parameters. A spatially coherent turbulent wind field is generated using the Davenport spectrum and harmonic superposition method, while an equivalent rain load is derived based on raindrop spectrum integration. Nonlinear dynamic time-history analysis is then conducted under multiple combinations of basic wind speeds and rainfall intensities, extracting engineering demand parameters such as conductor axial tension and pole-base bending moments. Based on probabilistic demand analysis, the relationship between engineering demand parameters and dual intensity measures is regressed in the logarithmic domain to construct bivariate fragility surfaces for both the conductors and the poles. Critical failure curves are obtained by intersecting the fragility surfaces with the 10% exceedance probability level, enabling rapid classification of structural risk under the joint effects of wind and rain. The results show that the regression model provides a high fit, effectively revealing that wind speed is the dominant control factor, while rainfall intensity serves as a secondary amplifying factor. The resulting critical failure curves can be directly used as operation and maintenance warning thresholds and can be coupled with observed and forecast meteorological data for time-varying risk assessment. These findings provide methodological support and engineering guidance for risk assessment, operation and maintenance decision-making, and resilience enhancement of distribution networks under multi-hazard coupling.

Authors

Publication Details

Journal
Energies
Published
2026-03-02
DOI
https://doi.org/10.3390/en19051236
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vulnerability Analysis of the Distribution Pole-Tower Conductor System Under Typhoon and Heavy Rainfall Disasters

Xunting Wang, Yuanzhi Li, Weibo Yuan, Haijun Yu et al.
Energies
Wind and Air Flow Studies
article

Vulnerability Analysis of the Distribution Pole-Tower Conductor System Under Typhoon and Heavy Rainfall Disasters

Xunting Wang, Yuanzhi Li, Weibo Yuan, Haijun Yu, Jinjin Ding, Lijun Wang
article en

Abstract

A vulnerability surface modeling method based on dual intensity metrics is proposed to assess the impact of typhoons and heavy rainfall disasters on the distribution pole-tower conductor system. A three-dimensional finite-element model is developed for a typical “three-pole four-conductor” distribution line, considering the uncertainties in both load-side and structural-side parameters. A spatially coherent turbulent wind field is generated using the Davenport spectrum and harmonic superposition method, while an equivalent rain load is derived based on raindrop spectrum integration. Nonlinear dynamic time-history analysis is then conducted under multiple combinations of basic wind speeds and rainfall intensities, extracting engineering demand parameters such as conductor axial tension and pole-base bending moments. Based on probabilistic demand analysis, the relationship between engineering demand parameters and dual intensity measures is regressed in the logarithmic domain to construct bivariate fragility surfaces for both the conductors and the poles. Critical failure curves are obtained by intersecting the fragility surfaces with the 10% exceedance probability level, enabling rapid classification of structural risk under the joint effects of wind and rain. The results show that the regression model provides a high fit, effectively revealing that wind speed is the dominant control factor, while rainfall intensity serves as a secondary amplifying factor. The resulting critical failure curves can be directly used as operation and maintenance warning thresholds and can be coupled with observed and forecast meteorological data for time-varying risk assessment. These findings provide methodological support and engineering guidance for risk assessment, operation and maintenance decision-making, and resilience enhancement of distribution networks under multi-hazard coupling.

EnergiesVol. 19(5)
Climate action
Openalex Percentile: Top 47%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.