Fungal emissions from air conditioning cooling coils

The fin-and-tube heat exchangers from air conditioning (AC) units are known locations of microbial growth within the built environment. Prior studies have documented the presence of potentially harmful fungal taxa on AC coils and noted the association of AC use and elevated respiratory symptoms in building occupants. This study aims to determine the rate at which fungi can be aerosolized from AC coils during normal operation. We investigated five AC units in commercial buildings in Southern CT, USA. At the end of the cooling season, we measured size-resolved aerosol concentrations (total, biological, fungal) upstream and downstream of the coils and applied ecological analysis to determine if fungal taxa on coil surfaces were emitted into downstream air. Coils were net sinks for a broad range of total aerosol sizes (0.4 to 20 μm). However, three of the five units were net emitters of bioaerosols with average emission rates of 5.6 × 10 7 to 7.2 × 10 7 biological particles hr -1 and 1.1 × 10 4 to 6.6 × 10 5 fungal spore equivalents hr -1 . Considering only measurements indicating the units as net sources, these AC units contributed approximately 34% of biological particle and 72% of airborne fungi in the downstream air. The two net sink coils were characterized by the presence of Leotiomycetes fungi , while the emitting coils had high abundance of Cladosporium , Penicillium, Aspergillus, Stachybotrys and Malassezia fungi. While most particles were found to deposit onto these coils, there is evidence that they can become net emitters of bioaerosols into air supplied indoors. • AC Coils were net sinks for a broad range of total aerosols in the upstream air. • 60% of the investigated AC units were net emitters of bioaerosols and fungi. • The non-emitting coils were characterized by Leotiomycetes and an elevated cooling load. • The emitting coil surfaces were abundant in Cladosporium , Penicillium, Aspergillus.

Authors

Institutions

Publication Details

Journal
Indoor Environments
Published
2026-03-02
DOI
https://doi.org/10.1016/j.indenv.2026.100162
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fungal emissions from air conditioning cooling coils

Mark J. Mendell, Drew R. Gentner, Mark Hernandez, Darryl M. Angel et al.
Indoor Environments
Indoor Air Quality and Microbial Exposure
article

Fungal emissions from air conditioning cooling coils

Mark J. Mendell, Drew R. Gentner, Mark Hernandez, Darryl M. Angel, Jeffrey A. Siegel, Jordan Peccia, Roger Sheu, Alexa Bakker, Irvan Luhung, Odessa Gomez
article en

Abstract

The fin-and-tube heat exchangers from air conditioning (AC) units are known locations of microbial growth within the built environment. Prior studies have documented the presence of potentially harmful fungal taxa on AC coils and noted the association of AC use and elevated respiratory symptoms in building occupants. This study aims to determine the rate at which fungi can be aerosolized from AC coils during normal operation. We investigated five AC units in commercial buildings in Southern CT, USA. At the end of the cooling season, we measured size-resolved aerosol concentrations (total, biological, fungal) upstream and downstream of the coils and applied ecological analysis to determine if fungal taxa on coil surfaces were emitted into downstream air. Coils were net sinks for a broad range of total aerosol sizes (0.4 to 20 μm). However, three of the five units were net emitters of bioaerosols with average emission rates of 5.6 × 10 7 to 7.2 × 10 7 biological particles hr -1 and 1.1 × 10 4 to 6.6 × 10 5 fungal spore equivalents hr -1 . Considering only measurements indicating the units as net sources, these AC units contributed approximately 34% of biological particle and 72% of airborne fungi in the downstream air. The two net sink coils were characterized by the presence of Leotiomycetes fungi , while the emitting coils had high abundance of Cladosporium , Penicillium, Aspergillus, Stachybotrys and Malassezia fungi. While most particles were found to deposit onto these coils, there is evidence that they can become net emitters of bioaerosols into air supplied indoors. • AC Coils were net sinks for a broad range of total aerosols in the upstream air. • 60% of the investigated AC units were net emitters of bioaerosols and fungi. • The non-emitting coils were characterized by Leotiomycetes and an elevated cooling load. • The emitting coil surfaces were abundant in Cladosporium , Penicillium, Aspergillus.

Indoor EnvironmentsVol. 3(2)
California Department of Public Health (US), University of Toronto (CA), University of Colorado Boulder (US), Yale University (US), Public Health Ontario (CA)
Affordable and clean energy
Openalex Percentile: Top 43%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.