Electrochemical Determination of Anticancer Drug Vandetanib on Glassy Carbon Electrode

This study presents a novel, simple, and cost-effective electrochemical method for the sensitive determination of Vandetanib (VAN), a clinically important tyrosine kinase inhibitor, using an unmodified glassy carbon electrode (GCE). The electrochemical behavior of VAN was investigated via cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over a wide pH range, an adsorption-controlled irreversible oxidation process involving equal numbers of protons and electrons, indicating a proton-coupled electron transfer mechanism. Optimization of experimental parameters, including pH, accumulation time, and accumulation potential, demonstrated that 0.5 M H2S04 (pH 0.3) and an accumulation time of 90 seconds provided optimal analytical performance. The DPV method exhibited excellent linearity between 2×10-8 M and 1.5×10-6 M VAN concentrations, with a low detection limit of 5.58×10-9 M. The proposed approach achieved high repeatability with relative standard deviations below 1.2%. Compared to previously reported methods involving complex electrode modifications, this work emphasizes the practicality of a bare GCE platform, eliminating the need for surface modification or surfactant addition. The method’s simplicity, sensitivity, and environmental friendliness make it a promising alternative for rapid VAN quantification.

Authors

Publication Details

Journal
DergiPark (Istanbul University)
Published
2025-09-24
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Determination of Anticancer Drug Vandetanib on Glassy Carbon Electrode

Cem Erkmen, Sevinç Kurbanoğlu, Gulsu Keles
DergiPark (Istanbul University)
Electrochemical sensors and biosensors
article

Electrochemical Determination of Anticancer Drug Vandetanib on Glassy Carbon Electrode

Cem Erkmen, Sevinç Kurbanoğlu, Gulsu Keles
article en

Abstract

This study presents a novel, simple, and cost-effective electrochemical method for the sensitive determination of Vandetanib (VAN), a clinically important tyrosine kinase inhibitor, using an unmodified glassy carbon electrode (GCE). The electrochemical behavior of VAN was investigated via cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over a wide pH range, an adsorption-controlled irreversible oxidation process involving equal numbers of protons and electrons, indicating a proton-coupled electron transfer mechanism. Optimization of experimental parameters, including pH, accumulation time, and accumulation potential, demonstrated that 0.5 M H2S04 (pH 0.3) and an accumulation time of 90 seconds provided optimal analytical performance. The DPV method exhibited excellent linearity between 2×10-8 M and 1.5×10-6 M VAN concentrations, with a low detection limit of 5.58×10-9 M. The proposed approach achieved high repeatability with relative standard deviations below 1.2%. Compared to previously reported methods involving complex electrode modifications, this work emphasizes the practicality of a bare GCE platform, eliminating the need for surface modification or surfactant addition. The method’s simplicity, sensitivity, and environmental friendliness make it a promising alternative for rapid VAN quantification.

DergiPark (Istanbul University)
Life in Land
Openalex Percentile: Top 34%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.