Urea detection in phosphate buffer and artificial urine

A simplified kinetic model for the quantitative analysis of a potentiometric, pH-based urea biosensor is presented. The device was an electrolyte–insulator–semiconductor ca- pacitor (EISCAP) with a pH-sensitive Ta2O5 gate functionalized by a polyallylamine hy- drochloride (PAH)/urease bilayer. Within the steady-state approximation, the kinetic equations yielded an implicit algebraic relation linking the bulk urea concentration to the local pH at the sensor surface. Numerical solution of this equation, combined with a fitting routine, provides the apparent Michaelis–Menten constant (K ) and the normalized max- imum reaction rate (k ). Validation against the literature data confirmed the reliability of the approach. Experimental results were then analyzed in both phosphate buffer (PBS) and artificial urine (AU), covering urea concentrations of 0.1–50 mM. The fitted parame- ters showed comparable K values of 10.9 mM (PBS) and 32.4 mM (AU), but strongly different k values: 2.2 10 (PBS) versus 8.6 10 (AU). The three-order reduc- tion in AU was attributed to the inhibitory effects inherent to complex biological fluids. These findings highlight the importance of the model-based quantitative analysis of EISCAP biosensors, enabling the accurate characterization of immobilized enzyme layers and guiding optimization for applications in realistic sample matrices.

Authors

Publication Details

Journal
RUNG
Published
2025-10-26
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Urea detection in phosphate buffer and artificial urine

Mkrtich A. Yeranosyan, Astghik Tsokolakyan, Vahe Buniatyan, Artem Badasyan et al.
RUNG
Analytical Chemistry and Sensors
article

Urea detection in phosphate buffer and artificial urine

Mkrtich A. Yeranosyan, Astghik Tsokolakyan, Vahe Buniatyan, Artem Badasyan, Karen Simonyan
article en

Abstract

A simplified kinetic model for the quantitative analysis of a potentiometric, pH-based urea biosensor is presented. The device was an electrolyte–insulator–semiconductor ca- pacitor (EISCAP) with a pH-sensitive Ta2O5 gate functionalized by a polyallylamine hy- drochloride (PAH)/urease bilayer. Within the steady-state approximation, the kinetic equations yielded an implicit algebraic relation linking the bulk urea concentration to the local pH at the sensor surface. Numerical solution of this equation, combined with a fitting routine, provides the apparent Michaelis–Menten constant (K ) and the normalized max- imum reaction rate (k ). Validation against the literature data confirmed the reliability of the approach. Experimental results were then analyzed in both phosphate buffer (PBS) and artificial urine (AU), covering urea concentrations of 0.1–50 mM. The fitted parame- ters showed comparable K values of 10.9 mM (PBS) and 32.4 mM (AU), but strongly different k values: 2.2 10 (PBS) versus 8.6 10 (AU). The three-order reduc- tion in AU was attributed to the inhibitory effects inherent to complex biological fluids. These findings highlight the importance of the model-based quantitative analysis of EISCAP biosensors, enabling the accurate characterization of immobilized enzyme layers and guiding optimization for applications in realistic sample matrices.

RUNG
Clean water and sanitation
Openalex Percentile: Top 40%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.