Validation of proton tests in air for detector calibration over a wide range of charge injection levels

We successfully evaluated the possibility of using a pulsed monoenergetic proton beam as a diagnostic tool for semiconductor detectors' response mapping at high charge densities. In order to ease the setup of the detector under test we explored the opportunity of performing tests with protons in air. We qualified a polyimide film window (Upilex-S, 7.5 μm nominal thickness) as proton extraction window and the energy loss in air as a function of distance. The tests have been carried out in vacuum first, in order to evaluate the energy loss due to the window only, followed by in-air tests aimed at the investigation of the total energy degradation of the extracted proton beam.

Authors

Publication Details

Journal
European XFEL Publication Database
Published
2024-09-09
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of proton tests in air for detector calibration over a wide range of charge injection levels

M. Porro, Schlee S., Georg Weidenspointner, Montemurro G.V. et al.
European XFEL Publication Database
Radiation Therapy and Dosimetry
article

Validation of proton tests in air for detector calibration over a wide range of charge injection levels

M. Porro, Schlee S., Georg Weidenspointner, Montemurro G.V., Guazzoni C., Carraresi L., Castoldi A.
article en

Abstract

We successfully evaluated the possibility of using a pulsed monoenergetic proton beam as a diagnostic tool for semiconductor detectors' response mapping at high charge densities. In order to ease the setup of the detector under test we explored the opportunity of performing tests with protons in air. We qualified a polyimide film window (Upilex-S, 7.5 μm nominal thickness) as proton extraction window and the energy loss in air as a function of distance. The tests have been carried out in vacuum first, in order to evaluate the energy loss due to the window only, followed by in-air tests aimed at the investigation of the total energy degradation of the extracted proton beam.

European XFEL Publication Database
Affordable and clean energy
Openalex Percentile: Top 41%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.