The importance of precise patient positioning in image guided radiotherapy: retrospective evaluation of estimated irradiation by registered daily cone-beam computed tomography images

Maximisation of irradiation accuracy of malignant tissues is a key challenge on the way to optimal radiotherapy. Strategies to improve irradiation accuracy should balance the expected clinical benefit against the feasibility and procedural demands of the method used. This pilot study marks an initial step toward retrospectively evaluating patient positioning accuracy, analysing CBCT images in relation to clinical outcomes, and estimating actual irradiation of target and surrounding tissues. The CBCT images were acquired from head and neck patients treated with the Halcyon V3.1 linear accelerator. The algorithms for precise alignment of images, which made it possible to estimate the detailed changes in tumour tissue density during treatment sessions were developed in the MATLAB. The recalculation of the actual dose showed that even small positioning errors can lead to significant changes in the delivered dose, especially in areas where critical organs are affected.

Authors

Publication Details

Journal
Lithuanian University of Health Sciences
Published
2025-11-06
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The importance of precise patient positioning in image guided radiotherapy: retrospective evaluation of estimated irradiation by registered daily cone-beam computed tomography images

Algimantas Kriščiukaitis, Reda Čerapaitė-Trušinskienė, Vita Špečkauskienė, Robertas Petrolis et al.
Lithuanian University of Health Sciences
Advanced Radiotherapy Techniques
article

The importance of precise patient positioning in image guided radiotherapy: retrospective evaluation of estimated irradiation by registered daily cone-beam computed tomography images

Algimantas Kriščiukaitis, Reda Čerapaitė-Trušinskienė, Vita Špečkauskienė, Robertas Petrolis, Diana Meilutytė-Lukauskienė, Greta Karpavičienė, Renata Paukštaitienė
article en

Abstract

Maximisation of irradiation accuracy of malignant tissues is a key challenge on the way to optimal radiotherapy. Strategies to improve irradiation accuracy should balance the expected clinical benefit against the feasibility and procedural demands of the method used. This pilot study marks an initial step toward retrospectively evaluating patient positioning accuracy, analysing CBCT images in relation to clinical outcomes, and estimating actual irradiation of target and surrounding tissues. The CBCT images were acquired from head and neck patients treated with the Halcyon V3.1 linear accelerator. The algorithms for precise alignment of images, which made it possible to estimate the detailed changes in tumour tissue density during treatment sessions were developed in the MATLAB. The recalculation of the actual dose showed that even small positioning errors can lead to significant changes in the delivered dose, especially in areas where critical organs are affected.

Lithuanian University of Health Sciences
Good health and well-being
Openalex Percentile: Top 23%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.