Reliability of Pulmonary Function Tests in Patients with Chronic Obstructive Pulmonary Disease
Fatma Arslan,1 Elif Şen,1 Burak Şirin,2 Nurdan Köktürk,3 Gaye Ulubay,4 Selma Aydogan Eroglu,5 Bilun Gemicioglu,6 Ãzlem Sönmez,7 İrem Şerifoğlu,8 Asli Gorek Dilektasli,9 Burcu Ãztürk Şahin,10 İlkay Doğan,11 Nermin Gürhan,12 Hakan Günen,5 Nihal Ensen6 1Department of Pulmonary Medicine, Ankara University Faculty of Medicine, Ankara, Türkiye; 2Faculty of Health Sciences, Department of Nursing, Tokat Gaziosmanpaşa University, Tokat, Türkiye; 3Department of Pulmonary Medicine, Gazi University Faculty of Medicine, Ankara, Türkiye; 4Department of Pulmonary Medicine, Başkent University Faculty of Medicine, Ankara, Türkiye; 5Department of Pulmonary Medicine, University of Health Sciences, Istanbul Sureyyapasa Chest Diseases and Thoracic Surgery Training and Research Hospital, Istanbul, Türkiye; 6Department of Chest Diseases, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Türkiye; 7Department of Chest Diseases, Ankara Atatürk Sanatorium Training and Research Hospital, Ankara, Türkiye; 8Department of Chest Diseases, Ankara Bilkent City Hospital, Ankara, Türkiye; 9Department of Chest Diseases, Uludağ University Faculty of Medicine, Bursa, Türkiye; 10Department of Chest Diseases, Gülhane Faculty of Medicine, University of Health Sciences, Ankara, Türkiye; 11Department of Biostatistics and Medical Informatics, Gaziantep University Faculty of Medicine, Gaziantep, Türkiye; 12OKA Congress and Health Tourism Institute, Tokat, TürkiyeCorrespondence: Fatma Arslan, Department of Pulmonary Medicine, Ankara University Faculty of Medicine, Cebeci Campus, Ankara, 06220, Türkiye, Email [email protected]: Chronic Obstructive Pulmonary Disease (COPD) is frequently underdiagnosed due to limited use and suboptimal quality of spirometry.Methods: This multicenter, prospective observational study aimed to assess the quality of spirometry tests in COPD patients across six tertiary care centers in Turkey. A total of 560 spirometry tests were independently evaluated by two pulmonologists, and inter-rater reliability was analyzed using Cohenâs Kappa.Results: The study included 124 women and 436 men, with a mean age of 65.9± 10.2 years. Spirometry patterns were interpreted as obstructive in 79.1% of tests, restrictive in 5.7%, mixed in 2.7%, normal in 6.7%, inconclusive in 5.5%, and as upper airway obstruction in 0.18% of cases (K=0.890). Routine post-bronchodilator testing was performed in 87.14% of the cases, while 12.85% were post-reversibility tests. Graphical data included volume-time curves (88.5%), flow-volume loops (99.6%), and inspiratory limbs (98.7%). Reference values were predominantly based on ECSC (86.4%), followed by GLI (8.9%) and NHANES (0.25%). Mean spirometric values included FEV1 (% predicted) 57.2%, FVC (% predicted) 72.7%, and FEV1/FVC 61.9%. Cough in the first second of FVC was observed in 17 (3%) (K=0.677), variable or insufficient effort 13.4% (K=0.563), mouth leak 1.8% (K=0.305), mouthpiece obstruction 0.5% (K=0.332), rapid expiration 1.8% (K=0.354), increased concavity 83% (K=0.683), and small airway obstruction 87% (K=0.709) were reported by interpreters.Conclusion: Spirometry reports frequently lack key information such as preliminary diagnoses, test indication, technician, and device details. ECSC is the most commonly used reference. Rates of inconclusive and erroneous testsâdue to variable or insufficient effort, mouth leak, mouthpiece obstruction, and rapid expirationâare low.Keywords: chronic obstructive pulmonary disease, COPD, pulmonary function tests, spirometry
Publication Details
- Journal
- Dove Medical Press (Taylor and Francis Group)
- Published
- 2026-01-21
- Primary Topic
- Chronic Obstructive Pulmonary Disease (COPD) Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00