Removal of erdosteine active substance from wastewater by chitosan/PVA and determination of the remaining erdosteine quantity by a new HPLC method

In this study, it was aimed to develop HPLC methods for the determination of erdosteine in standard working solutions and tablets. In addition, it was aimed to determine adsorption rates depending on time by using chitosan/pva adsorbents for the removal of erdosteine in wastewater by the developed HPLC method. In the HPLC method developed in this study, the C18 (Zorbax; 150 x 4.6 mm, 5 μm) column uses a mobile phase consisting of methanol-water (0.01 M Acetic acid; 65:35, V:V). Operating parameters consisting of a flow rate of 0.4 mL/min, a wavelength of 235 nm and an injection volume of 5 μL were used. While determining these parameters, firstly the data in the literature were examined and thus the most appropriate parameters were determined. It was determined that the method was linear in the concentration range of 0.1-25 μg/mL. A series of standard erdosteine solutions were prepared from the stock solution at concentrations of 0.1, 0.5, 1, 5, 10 and 25 μg/mL and their chromatograms were taken on HPLC. Chitosan/pva were used as adsorbents for erdosteine removal from wastewater. Accordingly, the adsorption process was carried out for 5, 10, 20, 40 and 80 min depending on the time. Afterwards, the amount of erdosteine in the obtained solutions was determined by HPLC. Results: A calibration curve was obtained by plotting the erdosteine peak area against the concentration of each solution. From the regression analysis of the calibration curve, the equation of the regression line is y = 14.33x + 0.6505; The correlation coefficient (r) for the active substance erdosteine was determined as 0.9995. The LOD value of the method is determined as 0,03 and the LOQ value is 0.01. Intraday accuracy and precision studies, %BH and %BSS were determined to be 6.5% and 0.387%, respectively. The recovery values of the method, for which validity tests were performed, were found to be 99.8% with the application of erdostin capsules containing erdosteine. In the adsorption process, 5.67, 11.47, 32.22, 76.25 and 76.8 percent erdosteine removal was achieved in 5-80 minutes, respectively. Accordingly, the highest adsorption percentage was reached at 76.8 at the end of 80 minutes. In studies carried out with HPLC, the quantification of the active substance erdosteine in commercial preparations was successfully carried out, and these methods were developed and validity tested. It was concluded that the methods can be successfully applied in studies for quality control purposes in pharmaceutical preparations, since validation studies have shown that the methods are sensitive, sensitive, selective, accurate and precise. It has also been determined that this method can be used for post-adsorption quantification.

Authors

Publication Details

Journal
Ataturk University - AVESIS
Published
2024-11-20
Primary Topic
Respiratory and Cough-Related Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Removal of erdosteine active substance from wastewater by chitosan/PVA and determination of the remaining erdosteine quantity by a new HPLC method

Alptuğ Atila, Mehmet Mekin Bingöl, Muhammet Sefa Yaralı, Hasan Can
Ataturk University - AVESIS
Respiratory and Cough-Related Research
article

Removal of erdosteine active substance from wastewater by chitosan/PVA and determination of the remaining erdosteine quantity by a new HPLC method

Alptuğ Atila, Mehmet Mekin Bingöl, Muhammet Sefa Yaralı, Hasan Can
article en

Abstract

In this study, it was aimed to develop HPLC methods for the determination of erdosteine in standard working solutions and tablets. In addition, it was aimed to determine adsorption rates depending on time by using chitosan/pva adsorbents for the removal of erdosteine in wastewater by the developed HPLC method. In the HPLC method developed in this study, the C18 (Zorbax; 150 x 4.6 mm, 5 μm) column uses a mobile phase consisting of methanol-water (0.01 M Acetic acid; 65:35, V:V). Operating parameters consisting of a flow rate of 0.4 mL/min, a wavelength of 235 nm and an injection volume of 5 μL were used. While determining these parameters, firstly the data in the literature were examined and thus the most appropriate parameters were determined. It was determined that the method was linear in the concentration range of 0.1-25 μg/mL. A series of standard erdosteine solutions were prepared from the stock solution at concentrations of 0.1, 0.5, 1, 5, 10 and 25 μg/mL and their chromatograms were taken on HPLC. Chitosan/pva were used as adsorbents for erdosteine removal from wastewater. Accordingly, the adsorption process was carried out for 5, 10, 20, 40 and 80 min depending on the time. Afterwards, the amount of erdosteine in the obtained solutions was determined by HPLC. Results: A calibration curve was obtained by plotting the erdosteine peak area against the concentration of each solution. From the regression analysis of the calibration curve, the equation of the regression line is y = 14.33x + 0.6505; The correlation coefficient (r) for the active substance erdosteine was determined as 0.9995. The LOD value of the method is determined as 0,03 and the LOQ value is 0.01. Intraday accuracy and precision studies, %BH and %BSS were determined to be 6.5% and 0.387%, respectively. The recovery values of the method, for which validity tests were performed, were found to be 99.8% with the application of erdostin capsules containing erdosteine. In the adsorption process, 5.67, 11.47, 32.22, 76.25 and 76.8 percent erdosteine removal was achieved in 5-80 minutes, respectively. Accordingly, the highest adsorption percentage was reached at 76.8 at the end of 80 minutes. In studies carried out with HPLC, the quantification of the active substance erdosteine in commercial preparations was successfully carried out, and these methods were developed and validity tested. It was concluded that the methods can be successfully applied in studies for quality control purposes in pharmaceutical preparations, since validation studies have shown that the methods are sensitive, sensitive, selective, accurate and precise. It has also been determined that this method can be used for post-adsorption quantification.

Ataturk University - AVESIS
Clean water and sanitation
Openalex Percentile: Top 41%
Respiratory and Cough-Related Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.