Increasing ultrasound field-of-view with reduced element count arrays containing large elements.

Several applications of medical ultrasound can benefit from a larger field of view (FOV). This study is aimed at increasing the FOV of linear array probes by increasing the element width. Coupled elements were used to imitate a larger element width. Through Fourier analysis, theoretical pressure amplitudes, and bandwidth estimates, coupled elements are shown to be close approximations of large elements. The effects of coupling on resolution, contrast, and speckle signal-to-noise ratio are investigated through phantom images and in-vivo images of a rabbit tumor reconstructed with plane-wave compounding. Furthermore, a positioning system was used to acquire data from a virtual large aperture with 120 mm FOV and 128 elements, collected in sections with a single probe. The Null Subtraction Imaging (NSI), Sign Coherence Factor (SCF), and Minimum Variance (MV) beamformers are compared for regaining resolution lost by an increased F-number. The NSI beamformer decreased Full-Width at Half-Max (FWHM) estimates of wire targets by 79% with coupling by 2 compared to uncoupled DAS. The MV beamformer was best for maintaining speckle statistics while improving resolution. Our results demonstrate how increased element width can increase FOV with no increase to element count.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-04-16
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increasing ultrasound field-of-view with reduced element count arrays containing large elements.

Michael L. Oelze, Mick Gardner, Rita J. Miller
PubMed
Ultrasound Imaging and Elastography
article

Increasing ultrasound field-of-view with reduced element count arrays containing large elements.

Michael L. Oelze, Mick Gardner, Rita J. Miller
article en

Abstract

Several applications of medical ultrasound can benefit from a larger field of view (FOV). This study is aimed at increasing the FOV of linear array probes by increasing the element width. Coupled elements were used to imitate a larger element width. Through Fourier analysis, theoretical pressure amplitudes, and bandwidth estimates, coupled elements are shown to be close approximations of large elements. The effects of coupling on resolution, contrast, and speckle signal-to-noise ratio are investigated through phantom images and in-vivo images of a rabbit tumor reconstructed with plane-wave compounding. Furthermore, a positioning system was used to acquire data from a virtual large aperture with 120 mm FOV and 128 elements, collected in sections with a single probe. The Null Subtraction Imaging (NSI), Sign Coherence Factor (SCF), and Minimum Variance (MV) beamformers are compared for regaining resolution lost by an increased F-number. The NSI beamformer decreased Full-Width at Half-Max (FWHM) estimates of wire targets by 79% with coupling by 2 compared to uncoupled DAS. The MV beamformer was best for maintaining speckle statistics while improving resolution. Our results demonstrate how increased element width can increase FOV with no increase to element count.

PubMed
University of Illinois Urbana-Champaign (US)
Openalex Percentile: Top 65%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Increasing ultrasound field-of-view with reduced element count arrays containing large elements. — Michael L. Oelze, Mick Gardner, et al. · PubMed (2026) | TGRS Research Map | TGRS