Accurate prediction of intradialytic hypo- and hypertension in hemodialysis patients: the dual-attention transformer model

Abstract Background and Hypothesis Intradialytic hypotension (IDH) and intradialytic hypertension (IDHTN) are frequent haemodialysis complications; each independently linked to increased cardiovascular risk and all-cause mortality. Existing predictive models often fail to capture the irregular nature of real-world haemodialysis data. The study objective was to develop an advanced machine learning architecture specifically designed for irregular time-series analysis of dialysis. Methods . We conducted a retrospective analysis of 1 300 haemodialysis patients, encompassing 182 111 sessions and 1 201 323 timestamped observations. Patients were randomly assigned to training (80%), validation (10%), and testing (10%) cohorts. IDH and IDHTN were defined by systolic blood pressure changes from pre-dialysis baseline: IDH is defined as a systolic blood pressure lower than 90 mmHg, and IDHTN is defined as an increase of ≥10 mmHg in systolic blood pressure without the occurrence of IDH. A Transformer model with dual-attention mechanism was developed for real-time event prediction. Performance was evaluated using area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), and F1 score. Results In the whole cohort, the incidence of IDH and IDHTN was 0.79% and 25.60%, respectively. The Transformer model demonstrated robust predictive accuracy in the test cohort, achieving AUROCs of 0.96 for IDH and 0.88 for IDHTN (all P < 0.01). The model’s high AUPRCs for both definitions confirmed its sensitivity in detecting early or moderate blood pressure fluctuations. To assess clinical utility, a complementary LightGBM model using pre-dialysis features predicted common symptoms or interventions with an accuracy of 0.926. Feature importance analyses validated established risk factors and identified key time-dependent covariates. Conclusion Our dual-attention Transformer model enables accurate, real-time prediction of intradialytic blood pressure abnormalities by effectively interpreting complex, asynchronous clinical data.

Authors

Institutions

Publication Details

Journal
Clinical Kidney Journal
Published
2026-02-26
DOI
https://doi.org/10.1093/ckj/sfag067
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate prediction of intradialytic hypo- and hypertension in hemodialysis patients: the dual-attention transformer model

Pei‐Yi Chen, Zengchun Ye, Hailong Liu, Yuehua Chen et al.
Clinical Kidney Journal
Dialysis and Renal Disease Management
article

Accurate prediction of intradialytic hypo- and hypertension in hemodialysis patients: the dual-attention transformer model

Pei‐Yi Chen, Zengchun Ye, Hailong Liu, Yuehua Chen, Zhaoyong Hu, Lanqing Han, Xilin Guan, Gexin Zhang, Yuanqing Li, Hui Peng
article en

Abstract

Abstract Background and Hypothesis Intradialytic hypotension (IDH) and intradialytic hypertension (IDHTN) are frequent haemodialysis complications; each independently linked to increased cardiovascular risk and all-cause mortality. Existing predictive models often fail to capture the irregular nature of real-world haemodialysis data. The study objective was to develop an advanced machine learning architecture specifically designed for irregular time-series analysis of dialysis. Methods . We conducted a retrospective analysis of 1 300 haemodialysis patients, encompassing 182 111 sessions and 1 201 323 timestamped observations. Patients were randomly assigned to training (80%), validation (10%), and testing (10%) cohorts. IDH and IDHTN were defined by systolic blood pressure changes from pre-dialysis baseline: IDH is defined as a systolic blood pressure lower than 90 mmHg, and IDHTN is defined as an increase of ≥10 mmHg in systolic blood pressure without the occurrence of IDH. A Transformer model with dual-attention mechanism was developed for real-time event prediction. Performance was evaluated using area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), and F1 score. Results In the whole cohort, the incidence of IDH and IDHTN was 0.79% and 25.60%, respectively. The Transformer model demonstrated robust predictive accuracy in the test cohort, achieving AUROCs of 0.96 for IDH and 0.88 for IDHTN (all P < 0.01). The model’s high AUPRCs for both definitions confirmed its sensitivity in detecting early or moderate blood pressure fluctuations. To assess clinical utility, a complementary LightGBM model using pre-dialysis features predicted common symptoms or interventions with an accuracy of 0.926. Feature importance analyses validated established risk factors and identified key time-dependent covariates. Conclusion Our dual-attention Transformer model enables accurate, real-time prediction of intradialytic blood pressure abnormalities by effectively interpreting complex, asynchronous clinical data.

Clinical Kidney Journal
Sun Yat-sen University (CN), Baylor College of Medicine (US), Pearl River Hydraulic Research Institute (CN), Third Affiliated Hospital of Sun Yat-sen University (CN), South China University of Technology (CN)
Good health and well-being
Openalex Percentile: Top 47%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.