Performance comparison of conductive textile electrodes in ECG monitoring

The implementation of textile electrodes offers the possibility of improving comfort and reducing the risk of allergic reactions of the measured subject, while also opening the door to non-medical devices for everyday life. The main objective of the experiment is to test and compare five conductive fabrics manufactured by Shieldex in terms of the quality of the measured electrocardiography (ECG) signals. For this experiment, 3 electrodes of each conductive material were made and tested on a sample of 20 volunteers. The electrodes were attached by an elastic band at the locations of selected standardized ECG leads, and Ag/AgCl electrodes were used as reference. Correlation coefficient (R), signal-to-noice ratio (SNR) and percentage root-mean-square deviation (PRD) applied to representative cardiac periods were used to evaluate the quality of the acquired data. Differences in the results of the evaluation parameters between the different positions were noted, and when the distribution of positions was neglected, it was discovered that the best results were obtained with Shieldex Silitex material and, on the contrary, the worst results were recorded with Shieldex Technik-tex P130 + B material. It was also found that the results were not significant between the materials and after visual inspection it can be concluded that all materials are suitable for ECG measurements.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-02-27
DOI
https://doi.org/10.3389/fbioe.2026.1772862
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance comparison of conductive textile electrodes in ECG monitoring

Michal Procházka, Lukáš Danys, Daniel Debnár, René Jaroš et al.
Frontiers in Bioengineering and Biotechnology
Non-Invasive Vital Sign Monitoring
article

Performance comparison of conductive textile electrodes in ECG monitoring

Michal Procházka, Lukáš Danys, Daniel Debnár, René Jaroš, Martin Lajdolf, Radek Martinek
article en

Abstract

The implementation of textile electrodes offers the possibility of improving comfort and reducing the risk of allergic reactions of the measured subject, while also opening the door to non-medical devices for everyday life. The main objective of the experiment is to test and compare five conductive fabrics manufactured by Shieldex in terms of the quality of the measured electrocardiography (ECG) signals. For this experiment, 3 electrodes of each conductive material were made and tested on a sample of 20 volunteers. The electrodes were attached by an elastic band at the locations of selected standardized ECG leads, and Ag/AgCl electrodes were used as reference. Correlation coefficient (R), signal-to-noice ratio (SNR) and percentage root-mean-square deviation (PRD) applied to representative cardiac periods were used to evaluate the quality of the acquired data. Differences in the results of the evaluation parameters between the different positions were noted, and when the distribution of positions was neglected, it was discovered that the best results were obtained with Shieldex Silitex material and, on the contrary, the worst results were recorded with Shieldex Technik-tex P130 + B material. It was also found that the results were not significant between the materials and after visual inspection it can be concluded that all materials are suitable for ECG measurements.

Frontiers in Bioengineering and BiotechnologyVol. 14
VSB - Technical University of Ostrava (CZ)
European Commission
Openalex Percentile: Top 42%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.