Status of the PAL-XFEL undulator program

Pohang Accelerator Laboratory (PAL) is developing a 0.1 nm SASE based FEL based on 10 GeV S-band linear accelerator named PAL-XFEL. At the first stage, PAL-XFEL needs two undulator lines for photon source. The hard Xray undulator line requires 18 units of 5 m long hybrid-type conventional planar undulator and soft X-ray line requires 6 units of 5 m long hybrid type planar undulator with additional few EPUs for final polarization control. PAL is developing undulator magnetic structure based on EU-XFEL concepts. The key parameters are min pole gap of 8.3 mm, with period length 26 mm (HXU), 35 mm (SXU), and 5.0 m magnetic length. . In this report, the prototyping, and the development of pole tuning procedure, the impact of the background field error, and the effects of the girder bending on the optical phase error will be presented.

Authors

Publication Details

Journal
European XFEL Publication Database
Published
2024-09-09
DOI
https://doi.org/10.1117/12.2182351.full
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Status of the PAL-XFEL undulator program

Kim D.-E., Cho Mh, Kang H.-S., Ko I.-S. et al.
European XFEL Publication Database
Particle Accelerators and Free-Electron Lasers
article

Status of the PAL-XFEL undulator program

Kim D.-E., Cho Mh, Kang H.-S., Ko I.-S., Park K.-H., Joachim Pflüger
article en

Abstract

Pohang Accelerator Laboratory (PAL) is developing a 0.1 nm SASE based FEL based on 10 GeV S-band linear accelerator named PAL-XFEL. At the first stage, PAL-XFEL needs two undulator lines for photon source. The hard Xray undulator line requires 18 units of 5 m long hybrid-type conventional planar undulator and soft X-ray line requires 6 units of 5 m long hybrid type planar undulator with additional few EPUs for final polarization control. PAL is developing undulator magnetic structure based on EU-XFEL concepts. The key parameters are min pole gap of 8.3 mm, with period length 26 mm (HXU), 35 mm (SXU), and 5.0 m magnetic length. . In this report, the prototyping, and the development of pole tuning procedure, the impact of the background field error, and the effects of the girder bending on the optical phase error will be presented.

European XFEL Publication Database
Openalex Percentile: Top 55%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.