Crevice corrosion of CuNi 90/10 under simulated macrofouling in temperate and tropical Australian marine environments

Copper-nickel 90/10 alloys are widely used in marine environments due to their resistance to corrosion and biofouling. However, the influence of macrofouling on localised corrosion remains poorly understood. This study examines the effect of simulated macrofouling-induced crevices on CuNi 90/10 corrosion using laser-cut plastic shims to replicate hard fouling geometries. Samples with crevice gaps of 50, 130 and 1,000 µm were exposed for 180 days at two Australian marine sites: temperate (Melbourne) and tropical (Cairns). Crevice corrosion was most severe in Melbourne, with the 130 µm gap showing the deepest attack. In Cairns, samples showed lower crevice corrosion despite heavier external fouling, suggesting that fouling composition and protective calcareous deposits may mitigate attack. Crevice interiors lacked Desulfobacterota and exhibited less diverse communities with greater inter-replicate variability at both sites than outside surfaces. These results highlight the combined influence of environment, crevice geometry, corrosion product films, and biofouling composition on crevice corrosion of CuNi 90/10.

Authors

Institutions

Publication Details

Journal
Biofouling
Published
2026-02-27
DOI
https://doi.org/10.1080/08927014.2026.2630944
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Crevice corrosion of CuNi 90/10 under simulated macrofouling in temperate and tropical Australian marine environments

M A Javed, R. Piola, W C Neil, S A Wade
Biofouling
Corrosion Behavior and Inhibition
article

Crevice corrosion of CuNi 90/10 under simulated macrofouling in temperate and tropical Australian marine environments

M A Javed, R. Piola, W C Neil, S A Wade
article en

Abstract

Copper-nickel 90/10 alloys are widely used in marine environments due to their resistance to corrosion and biofouling. However, the influence of macrofouling on localised corrosion remains poorly understood. This study examines the effect of simulated macrofouling-induced crevices on CuNi 90/10 corrosion using laser-cut plastic shims to replicate hard fouling geometries. Samples with crevice gaps of 50, 130 and 1,000 µm were exposed for 180 days at two Australian marine sites: temperate (Melbourne) and tropical (Cairns). Crevice corrosion was most severe in Melbourne, with the 130 µm gap showing the deepest attack. In Cairns, samples showed lower crevice corrosion despite heavier external fouling, suggesting that fouling composition and protective calcareous deposits may mitigate attack. Crevice interiors lacked Desulfobacterota and exhibited less diverse communities with greater inter-replicate variability at both sites than outside surfaces. These results highlight the combined influence of environment, crevice geometry, corrosion product films, and biofouling composition on crevice corrosion of CuNi 90/10.

BiofoulingVol. 42(4)
Defence Science and Technology Group (AU), Flinders University (AU), Australian Health Practitioner Regulation Agency (AU), Swinburne University of Technology (AU)
Life below water
Openalex Percentile: Top 42%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.