Umbilical Coiling Index, Doppler Parameters, and Cord Blood Gas Analysis: Lack of Correlation in Uncomplicated Term Pregnancies

<b>Background/Objectives</b>: In this study, we aimed to evaluate whether neonatal ischemia-modified albumin (IMA) and umbilical venous cord blood gas parameters are associated with antenatal markers of fetal well-being, including the umbilical coiling index (UCI) and umbilical artery (UA) and middle cerebral artery (MCA) Doppler indices. <b>Methods</b>: For this prospective observational study, sixty-five low-risk term pregnancies (≥37 weeks) were included. Prenatal ultrasound was used to measure the UCI and UA/MCA Doppler indices. At delivery, umbilical venous cord blood gas and serum IMA analyses were performed. Maternal and neonatal data (birth weight, 5 min Apgar score, NICU admission, sex, and delivery mode) were recorded, and correlations and group comparisons were performed (<i>p</i> < 0.05). <b>Results</b>: The UCI ranged from 0.210 to 0.471 coil/cm (mean 0.337). The UA and MCA Doppler indices were within the reference ranges. The UCI showed no significant correlation with umbilical venous blood gas values, IMA, UA/MCA Doppler indices, gestational age/weeks, or 5 min Apgar score. The UA S/D ratio and UA resistive index (RI) were negatively correlated with birth weight (<i>p</i> < 0.05). Umbilical venous pH was positively correlated with the 5 min Apgar score, whereas venous pCO<sub>2</sub> was negatively correlated with the 5 min Apgar score (both <i>p</i> < 0.05). Newborns with venous pH < 7.32 had higher cesarean delivery rates and higher rooming-in rates. Newborns admitted to the NICU had higher mean UA systolic velocity/diastolic velocity (S/D) and UA pulsatility index (PI) and lower venous pH. <b>Conclusions</b>: In low-risk term pregnancies, the UCI was not associated with cord blood gas parameters, IMA, or UA/MCA Doppler indices. These results suggest that the UCI may have limited clinical utility as a predictor of early neonatal acidosis or oxidative stress in a strictly low-risk population.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-02-27
DOI
https://doi.org/10.3390/jcm15051810
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Umbilical Coiling Index, Doppler Parameters, and Cord Blood Gas Analysis: Lack of Correlation in Uncomplicated Term Pregnancies

S. Ayan, Süleyman Caner Karahan, Zeynep Begum Celik, Gulseren Dinc
Journal of Clinical Medicine
Pregnancy and preeclampsia studies
article

Umbilical Coiling Index, Doppler Parameters, and Cord Blood Gas Analysis: Lack of Correlation in Uncomplicated Term Pregnancies

S. Ayan, Süleyman Caner Karahan, Zeynep Begum Celik, Gulseren Dinc
article en

Abstract

<b>Background/Objectives</b>: In this study, we aimed to evaluate whether neonatal ischemia-modified albumin (IMA) and umbilical venous cord blood gas parameters are associated with antenatal markers of fetal well-being, including the umbilical coiling index (UCI) and umbilical artery (UA) and middle cerebral artery (MCA) Doppler indices. <b>Methods</b>: For this prospective observational study, sixty-five low-risk term pregnancies (≥37 weeks) were included. Prenatal ultrasound was used to measure the UCI and UA/MCA Doppler indices. At delivery, umbilical venous cord blood gas and serum IMA analyses were performed. Maternal and neonatal data (birth weight, 5 min Apgar score, NICU admission, sex, and delivery mode) were recorded, and correlations and group comparisons were performed (<i>p</i> < 0.05). <b>Results</b>: The UCI ranged from 0.210 to 0.471 coil/cm (mean 0.337). The UA and MCA Doppler indices were within the reference ranges. The UCI showed no significant correlation with umbilical venous blood gas values, IMA, UA/MCA Doppler indices, gestational age/weeks, or 5 min Apgar score. The UA S/D ratio and UA resistive index (RI) were negatively correlated with birth weight (<i>p</i> < 0.05). Umbilical venous pH was positively correlated with the 5 min Apgar score, whereas venous pCO<sub>2</sub> was negatively correlated with the 5 min Apgar score (both <i>p</i> < 0.05). Newborns with venous pH < 7.32 had higher cesarean delivery rates and higher rooming-in rates. Newborns admitted to the NICU had higher mean UA systolic velocity/diastolic velocity (S/D) and UA pulsatility index (PI) and lower venous pH. <b>Conclusions</b>: In low-risk term pregnancies, the UCI was not associated with cord blood gas parameters, IMA, or UA/MCA Doppler indices. These results suggest that the UCI may have limited clinical utility as a predictor of early neonatal acidosis or oxidative stress in a strictly low-risk population.

Journal of Clinical MedicineVol. 15(5)
Karadeniz Technical University (TR), State Hospital (GB), Sivas State Hospital (TR)
Karadeniz Teknik Üniversitesi
Good health and well-being
Openalex Percentile: Top 38%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.