Brain tissue polarimetry under simulated intraoperative conditions: Effects of edema and temperature

In neurosurgical oncology, maximizing tumor resection while preserving neurological function remains a critical challenge, particularly in glioma surgery where tumor borders are difficult to distinguish intraoperatively. Polarimetry-based imaging has emerged as a promising technique for visualizing white matter fiber tracts and differentiating healthy from neoplastic brain tissue. This study evaluates whether brain edema and temperature variations influence polarimetric parameters, potentially introducing noise and complicating intraoperative imaging. To model edema, fresh ex vivo calf brain samples were immersed in distilled water. Polarimetric parameters including depolarization, linear retardance, and the azimuth of the optical axis, were measured at multiple time points over three hours and a half using a wide-field imaging Mueller polarimetric setup. Results show that water absorption affects all polarimetric parameters and complicates fiber tract visualization. We also investigated whether temperature changes influenced polarimetric markers, but found no significant effect. These findings demonstrate that brain edema might alter polarimetric markers and act as a confounding factor in intraoperative imaging, potentially affecting tumor border visualization. The in vivo impact of brain edema remains unclear, and further studies are needed to refine polarimetric imaging for surgical guidance in glioma resection.

Authors

Institutions

Publication Details

Journal
Journal of Innovative Optical Health Sciences
Published
2026-02-27
DOI
https://doi.org/10.1142/s1793545826500045
Primary Topic
Optical Polarization and Ellipsometry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Brain tissue polarimetry under simulated intraoperative conditions: Effects of edema and temperature

Theotim Lucas, Arnas Jankauskas, David Hasler, Ardit Sakiri et al.
Journal of Innovative Optical Health Sciences
Optical Polarization and Ellipsometry
article

Brain tissue polarimetry under simulated intraoperative conditions: Effects of edema and temperature

Theotim Lucas, Arnas Jankauskas, David Hasler, Ardit Sakiri, Theoni Maragkou, Stefano Moriconi, Elea Gros, Richard McKinley, Tatiana Novikova, Philippe Schucht, Omar Rodriguez-Nunez
article en

Abstract

In neurosurgical oncology, maximizing tumor resection while preserving neurological function remains a critical challenge, particularly in glioma surgery where tumor borders are difficult to distinguish intraoperatively. Polarimetry-based imaging has emerged as a promising technique for visualizing white matter fiber tracts and differentiating healthy from neoplastic brain tissue. This study evaluates whether brain edema and temperature variations influence polarimetric parameters, potentially introducing noise and complicating intraoperative imaging. To model edema, fresh ex vivo calf brain samples were immersed in distilled water. Polarimetric parameters including depolarization, linear retardance, and the azimuth of the optical axis, were measured at multiple time points over three hours and a half using a wide-field imaging Mueller polarimetric setup. Results show that water absorption affects all polarimetric parameters and complicates fiber tract visualization. We also investigated whether temperature changes influenced polarimetric markers, but found no significant effect. These findings demonstrate that brain edema might alter polarimetric markers and act as a confounding factor in intraoperative imaging, potentially affecting tumor border visualization. The in vivo impact of brain edema remains unclear, and further studies are needed to refine polarimetric imaging for surgical guidance in glioma resection.

Journal of Innovative Optical Health Sciences
University of Bern (CH), Centre National de la Recherche Scientifique (FR), Bern University of Applied Sciences (CH), École Polytechnique (FR), Florida International University (US), University Hospital of Bern (CH)
Openalex Percentile: Top 42%
Optical Polarization and Ellipsometry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.