Development and Validation of a Transient Electro-Thermo- Mechanical Model for Parabolic Dish Micro Gas Turbines

Small-scale concentrated solar power (CSP) systems coupled with micro gas turbines (MGTs) offer a promising solution for decentralised and sustainable power generation. However, CSP–MGT systems are subject to pronounced transient behaviour during start-up and operation due to fluctuating solar irradiance, making accurate transient modelling essential. This work introduces a fully coupled transient electro-thermo-mechanical model of a CSP-driven micro gas turbine, explicitly linking thermal transients and heat soakage effects to electrical performance during start-up. Unlike existing models, the proposed approach captures the interaction between turbomachinery thermal inertia, shaft dynamics, and detailed electrical machine and power converter losses under real-world transient operating conditions. The model integrates thermodynamic, mechanical, electrical, and control subsystems within a unified framework using a lumped-volume formulation suitable for real-time-capable simulations. To improve prediction accuracy at low rotational speeds, a dedicated interpolation strategy for turbomachinery performance maps is implemented. The model is validated at both component and system levels using experimental data from a 6 kWe CSP–MGT test facility. The results show good agreement with measurements, with maximum deviations of approximately 8% in receiver outlet temperature and less than 6% in air mass flow rate. The findings demonstrate that accounting for heat soakage is critical for a realistic prediction of thermal and electrical transients, as neglecting thermal inertia leads to an underestimation of the start-up electrical energy consumption by up to 140%, highlighting the dominant role of thermal mass effects in small-scale micro gas turbines compared to larger systems. The proposed model provides a robust tool for analysing start-up behaviour and supports improved control and operational strategy development for CSP–MGT systems under variable solar conditions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-02-27
DOI
https://doi.org/10.3390/en19051188
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Transient Electro-Thermo- Mechanical Model for Parabolic Dish Micro Gas Turbines

Jafar Al-Zaili, Shahrbanoo Shamekhi Amiri, A. I. Sayma
Energies
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Development and Validation of a Transient Electro-Thermo- Mechanical Model for Parabolic Dish Micro Gas Turbines

Jafar Al-Zaili, Shahrbanoo Shamekhi Amiri, A. I. Sayma
article en

Abstract

Small-scale concentrated solar power (CSP) systems coupled with micro gas turbines (MGTs) offer a promising solution for decentralised and sustainable power generation. However, CSP–MGT systems are subject to pronounced transient behaviour during start-up and operation due to fluctuating solar irradiance, making accurate transient modelling essential. This work introduces a fully coupled transient electro-thermo-mechanical model of a CSP-driven micro gas turbine, explicitly linking thermal transients and heat soakage effects to electrical performance during start-up. Unlike existing models, the proposed approach captures the interaction between turbomachinery thermal inertia, shaft dynamics, and detailed electrical machine and power converter losses under real-world transient operating conditions. The model integrates thermodynamic, mechanical, electrical, and control subsystems within a unified framework using a lumped-volume formulation suitable for real-time-capable simulations. To improve prediction accuracy at low rotational speeds, a dedicated interpolation strategy for turbomachinery performance maps is implemented. The model is validated at both component and system levels using experimental data from a 6 kWe CSP–MGT test facility. The results show good agreement with measurements, with maximum deviations of approximately 8% in receiver outlet temperature and less than 6% in air mass flow rate. The findings demonstrate that accounting for heat soakage is critical for a realistic prediction of thermal and electrical transients, as neglecting thermal inertia leads to an underestimation of the start-up electrical energy consumption by up to 140%, highlighting the dominant role of thermal mass effects in small-scale micro gas turbines compared to larger systems. The proposed model provides a robust tool for analysing start-up behaviour and supports improved control and operational strategy development for CSP–MGT systems under variable solar conditions.

EnergiesVol. 19(5)
Northampton Community College (US), City, University of London (GB), Brunel University of London (GB)
Openalex Percentile: Top 42%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.