Laser-Induced Graphite Multi-Ion Sensor for Real-Time Assessment of Fucoxanthin Therapy in Alcoholic Liver Disease
Oxidative stress has been recognized as a pivotal mechanism for disrupting cellular ion homeostasis and contributes to the pathogenesis of associated conditions, including alcoholic liver disease (ALD). The real-time and accurate detection of cellular ion concentrations is crucial for understanding oxidative stress-related disease pathogenesis and developing effective interventions. Herein, a multichannel electrochemical sensor was developed to simultaneously detect dynamic changes in extracellular H<sup>+</sup>, Ca<sup>2+</sup>, K<sup>+</sup>, and Na<sup>+</sup> in HepG2 cells within an ALD cell model. This sensor was fabricated based on patterned laser-induced graphite electrodes modified with H<sup>+</sup>-sensitive polyaniline and Ca<sup>2+</sup>/K<sup>+</sup>/Na<sup>+</sup>-selective membranes. Evaluation in buffered solution systems confirmed that the sensor possessed high sensitivity, excellent anti-interference capability, along with good selectivity, reversibility, and stability in detecting all four target ions. When used to monitor extracellular ion dynamics during ethanol-induced oxidative stress and therapeutic processes in HepG2 cells, it revealed the relationship between ethanol-induced extracellular acidification, K<sup>+</sup> efflux, intracellular Ca<sup>2+</sup> overload, and oxidative stress. It also demonstrated that ion disorders were significantly alleviated by nutritional intervention with fucoxanthin and its targeted derivatives. This sensor provides an efficient tool for studying ion homeostasis imbalance mechanisms in oxidative stress-related disease and holds potential applications in cell metabolism monitoring, as well as the fabrication and application of real-time multi-ion sensors.
Authors
- Wentao Su (ORCID: https://orcid.org/0000-0002-5233-1093)
- Tianxi Yang (ORCID: https://orcid.org/0000-0003-4197-9262)
- Xu Zhong (ORCID: https://orcid.org/0000-0002-0619-8949)
- Xi Liu (ORCID: https://orcid.org/0000-0002-6741-4094)
- Yun Ma (ORCID: https://orcid.org/0000-0002-4672-3584)
- Shitao Nie
- Jie Song
- Mingqian Tan
- Bing Yin
Institutions
- University of British Columbia (CA)
- King's College London (GB)
- Dalian University of Technology (CN)
- Food and Nutrition Service (US)
- Institut thématique Immunologie, inflammation, infectiologie et microbiologie (FR)
- Institute of Food Science and Technology (CN)
- Smart Material (Germany) (DE)
- Dalian Polytechnic University (CN)
Publication Details
- Journal
- Analytical Chemistry
- Published
- 2026-02-26
- DOI
- https://doi.org/10.1021/acs.analchem.5c06878
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00