Untargeted Sweat and Sebum Volatilomics by HS-SPME-GC/ToF-MS for the Identification of SARS-CoV-2-Associated Biomarkers

<b>Background/Objectives</b>: The COVID-19 pandemic has emphasized the urgent need for non-invasive diagnostic strategies. While breath analysis has been widely investigated, sweat and sebum remain largely unexplored, despite being abundant, chemically diverse, and easily collected. This exploratory study presents a proof-of-concept workflow to evaluate their potential for infection biomarker discovery. <b>Methods</b>: Samples from 51 subjects were analyzed by headspace solid-phase microextraction coupled with gas chromatography and time-of-flight mass spectrometry (HS-SPME-GC/ToF-MS). Over 8000 untargeted volatile compounds were detected, reflecting the high complexity of these matrices. <b>Results</b>: Data refinement and chemometric modelling using principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA) revealed robust separation between SARS-CoV-2-positive Patients and Controls. Classification accuracies consistently exceeded 95%, demonstrating the robust discriminative performance of the approach. Among the detected volatiles, 2-methylbenzenemethanol acetate emerged as the most informative compound, representing a potential biomarker candidate. <b>Conclusions</b>: This work shows that the sweat and sebum volatilome can be exploited for clinical applications. The workflow integrates non-invasive sampling, comprehensive chromatographic profiling, and advanced statistical modelling, representing a methodological contribution to analytical chemistry. Beyond COVID-19, the strategy provides a potential framework for volatile organic compound (VOC)-based diagnostics across different diseases and supports future development of sensor technologies for translation into healthcare practice.

Authors

Institutions

Publication Details

Journal
Metabolites
Published
2026-02-27
DOI
https://doi.org/10.3390/metabo16030158
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Untargeted Sweat and Sebum Volatilomics by HS-SPME-GC/ToF-MS for the Identification of SARS-CoV-2-Associated Biomarkers

Bruno Grassi, Giovanni Baldassarre, Emanuele Boselli, Lucrezia Zuccarelli et al.
Metabolites
Advanced Chemical Sensor Technologies
article

Untargeted Sweat and Sebum Volatilomics by HS-SPME-GC/ToF-MS for the Identification of SARS-CoV-2-Associated Biomarkers

Bruno Grassi, Giovanni Baldassarre, Emanuele Boselli, Lucrezia Zuccarelli, Edoardo Longo, Stefano Cesco, Carlo Tascini, Emanuela Sozio
article en

Abstract

<b>Background/Objectives</b>: The COVID-19 pandemic has emphasized the urgent need for non-invasive diagnostic strategies. While breath analysis has been widely investigated, sweat and sebum remain largely unexplored, despite being abundant, chemically diverse, and easily collected. This exploratory study presents a proof-of-concept workflow to evaluate their potential for infection biomarker discovery. <b>Methods</b>: Samples from 51 subjects were analyzed by headspace solid-phase microextraction coupled with gas chromatography and time-of-flight mass spectrometry (HS-SPME-GC/ToF-MS). Over 8000 untargeted volatile compounds were detected, reflecting the high complexity of these matrices. <b>Results</b>: Data refinement and chemometric modelling using principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA) revealed robust separation between SARS-CoV-2-positive Patients and Controls. Classification accuracies consistently exceeded 95%, demonstrating the robust discriminative performance of the approach. Among the detected volatiles, 2-methylbenzenemethanol acetate emerged as the most informative compound, representing a potential biomarker candidate. <b>Conclusions</b>: This work shows that the sweat and sebum volatilome can be exploited for clinical applications. The workflow integrates non-invasive sampling, comprehensive chromatographic profiling, and advanced statistical modelling, representing a methodological contribution to analytical chemistry. Beyond COVID-19, the strategy provides a potential framework for volatile organic compound (VOC)-based diagnostics across different diseases and supports future development of sensor technologies for translation into healthcare practice.

MetabolitesVol. 16(3)
University of Udine (IT), Free University of Bozen-Bolzano (IT), Ospedale Santa Maria della Misericordia di Udine (IT)
Reduced inequalities
Openalex Percentile: Top 43%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.