Device closure of a small atrial septal defect with an unusual set of post-operative complications

Percutaneous closure of secundum atrial septal defects (ASDs) is a standard procedure. However, it is not without risk, and complications can be severe even in apparently straightforward cases. A 19-year-old male (80 kg, 170 cm), with a history of infantile strabismus, underwent percutaneous closure of a small (11 × 12 mm) secundum ASD with adequate rims using an 18 mm Occlutech septal occluder.The procedure was performed under general anesthesia and transesophageal echocardiography (TEE) guidance, and the device initially appeared well positioned. The following day, routine transthoracic echocardiography (TTE) failed to visualize the device, and a diagnostic error led to the device’s location being misinterpreted as a pulmonary artery on fluoroscopy. Emergency surgery was performed to remove the device and close the defect, but the device was not found. Post-operatively, real-time 3D Computed Tomography (CT) located the device in the aortic arch. It was subsequently retrieved percutaneously. During extubation, the patient developed agitation and confusion, and a cranial CT revealed a right posterior cerebral artery infarction, resulting in left homonymous hemianopsia. Follow-up neurological assessment and MRI confirmed the ischemic sequelae. Interestingly, the patient’s pre-existing strabismus completely resolved. The potential etiology of the cerebral ischemic event includes thromboembolism from the device or catheter manipulation. This case highlights that severe complications, including device embolization to unexpected systemic locations and subsequent cerebrovascular events, can occur even in low-risk ASD closures. It underscores the critical importance of meticulous, multi-view intra procedural and post-procedural imaging to prevent diagnostic errors. The unexpected resolution of strabismus following a posterior cerebral artery infarct suggests a complex neuro-ophthalmological phenomenon requiring further investigation.

Authors

Institutions

Publication Details

Journal
BMC Cardiovascular Disorders
Published
2026-02-27
DOI
https://doi.org/10.1186/s12872-026-05643-w
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Device closure of a small atrial septal defect with an unusual set of post-operative complications

O. Celik, Cengiz Demir, Halil Ibrahim Balsak, Volkan Dogan et al.
BMC Cardiovascular Disorders
Cardiovascular and Diving-Related Complications
article

Device closure of a small atrial septal defect with an unusual set of post-operative complications

O. Celik, Cengiz Demir, Halil Ibrahim Balsak, Volkan Dogan, Utku Cenikli
article en

Abstract

Percutaneous closure of secundum atrial septal defects (ASDs) is a standard procedure. However, it is not without risk, and complications can be severe even in apparently straightforward cases. A 19-year-old male (80 kg, 170 cm), with a history of infantile strabismus, underwent percutaneous closure of a small (11 × 12 mm) secundum ASD with adequate rims using an 18 mm Occlutech septal occluder.The procedure was performed under general anesthesia and transesophageal echocardiography (TEE) guidance, and the device initially appeared well positioned. The following day, routine transthoracic echocardiography (TTE) failed to visualize the device, and a diagnostic error led to the device’s location being misinterpreted as a pulmonary artery on fluoroscopy. Emergency surgery was performed to remove the device and close the defect, but the device was not found. Post-operatively, real-time 3D Computed Tomography (CT) located the device in the aortic arch. It was subsequently retrieved percutaneously. During extubation, the patient developed agitation and confusion, and a cranial CT revealed a right posterior cerebral artery infarction, resulting in left homonymous hemianopsia. Follow-up neurological assessment and MRI confirmed the ischemic sequelae. Interestingly, the patient’s pre-existing strabismus completely resolved. The potential etiology of the cerebral ischemic event includes thromboembolism from the device or catheter manipulation. This case highlights that severe complications, including device embolization to unexpected systemic locations and subsequent cerebrovascular events, can occur even in low-risk ASD closures. It underscores the critical importance of meticulous, multi-view intra procedural and post-procedural imaging to prevent diagnostic errors. The unexpected resolution of strabismus following a posterior cerebral artery infarct suggests a complex neuro-ophthalmological phenomenon requiring further investigation.

BMC Cardiovascular Disorders
Sivas State Hospital (TR), Muğla University (TR)
Good health and well-being
Openalex Percentile: Top 41%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.