Mechanically governed fracture resistance of biodegradable Zn-Cu alloy stents: Role of ring-length optimized structural design

Zinc alloys containing copper, featuring highly soluble biocompatible elements, are widely regarded as one of the most promising candidates for use in biodegradable stents. However, suboptimal structural designs in biodegradable zinc alloy stents often lead to immediate strut fracture upon deployment. Although ring length plays a critical role in this failure mechanism, systematic studies focusing on enhancing fracture resistance through structural design-rather than material modification-remain limited. This study engineered three distinct ring length configurations (approximating radial strengths of 89 kPa, 120 kPa, and 150 kPa) to elucidate structural optimization effects on fracture resistance during biodegradable zinc alloy stents expansion. Our results demonstrate that stents with 89 kPa and 120 kPa radial strength exhibit superior fracture resistance, whereas the 150 kPa design shows significantly elevated fracture incidence. Mechanistic analyses reveal that the capacity for geometric plasticity accommodation constitutes the dominant fracture-resistant mechanism, beyond intrinsic material properties. This capacity is achieved through stress redistribution, which mitigates localized peak stress. Optimized stents achieved uniform expansion, perfect vessel apposition, and preserved structural continuity. Histological analysis revealed a confluent endothelial layer covering the stent struts at 1 month. These findings reveal a direct relationship between structural plasticity accommodation capacity and mechanical integrity preservation, providing critical insights for developing next-generation bioresorbable stents with enhanced structural reliability.

Authors

Institutions

Publication Details

Journal
Bioactive Materials
Published
2026-02-27
DOI
https://doi.org/10.1016/j.bioactmat.2026.02.015
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanically governed fracture resistance of biodegradable Zn-Cu alloy stents: Role of ring-length optimized structural design

P. L. Zeng, Yafei Li, Shaokang Guan, Yufeng Zheng et al.
Bioactive Materials
Magnesium Alloys: Properties and Applications
article

Mechanically governed fracture resistance of biodegradable Zn-Cu alloy stents: Role of ring-length optimized structural design

P. L. Zeng, Yafei Li, Shaokang Guan, Yufeng Zheng, Lei Wang, Jiang Liu, Jie Li, Hongtao Yang
article en

Abstract

Zinc alloys containing copper, featuring highly soluble biocompatible elements, are widely regarded as one of the most promising candidates for use in biodegradable stents. However, suboptimal structural designs in biodegradable zinc alloy stents often lead to immediate strut fracture upon deployment. Although ring length plays a critical role in this failure mechanism, systematic studies focusing on enhancing fracture resistance through structural design-rather than material modification-remain limited. This study engineered three distinct ring length configurations (approximating radial strengths of 89 kPa, 120 kPa, and 150 kPa) to elucidate structural optimization effects on fracture resistance during biodegradable zinc alloy stents expansion. Our results demonstrate that stents with 89 kPa and 120 kPa radial strength exhibit superior fracture resistance, whereas the 150 kPa design shows significantly elevated fracture incidence. Mechanistic analyses reveal that the capacity for geometric plasticity accommodation constitutes the dominant fracture-resistant mechanism, beyond intrinsic material properties. This capacity is achieved through stress redistribution, which mitigates localized peak stress. Optimized stents achieved uniform expansion, perfect vessel apposition, and preserved structural continuity. Histological analysis revealed a confluent endothelial layer covering the stent struts at 1 month. These findings reveal a direct relationship between structural plasticity accommodation capacity and mechanical integrity preservation, providing critical insights for developing next-generation bioresorbable stents with enhanced structural reliability.

Bioactive MaterialsVol. 61
Changsha Medical University (CN), Peking University (CN), Zhengzhou University (CN), Beihang University (CN)
Openalex Percentile: Top 42%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.