Accuracy of Deep Learning-Driven MR Arthrography of the Shoulder: Compressed 3D in Comparison to Standard FSE Sequences

Background/Objectives: Magnetic resonance arthrography is the reference standard for evaluating glenoid labral lesions. Deep learning (DL) reconstruction algorithms may accelerate 3D acquisitions while maintaining image quality. This study assesses the diagnostic accuracy of DL-based isotropic 3D MR imaging for detecting glenoid labral lesions. Methods: This prospective study included 128 consecutive patients (79 men, 49 women; mean age 38.4 years) undergoing shoulder MR arthrography between June 2023 and April 2025. DL-based 3D sequences (acquisition time: 3:26) were compared with conventional multiplanar TSE and PD-FS sequences (acquisition time: 24–28 min). Two independent radiologists assessed glenoid labral lesions, bone marrow edema, and rotator cuff abnormalities using a four-point Likert scale. Sensitivity, specificity, and interobserver agreement were calculated. Results: DL-based 3D sequences demonstrated 94.7–95.1% sensitivity and 100% specificity for glenoid labral lesions, with excellent interobserver agreement (κ = 0.812). The area under the ROC curve was 0.894. Combined 3D protocols (T1 + PD-FS) showed superior accuracy (97.8%) compared to single sequences (90.5%, p = 0.012). For bone marrow edema, sensitivity was 82.9% with 100% specificity. Rotator cuff evaluation achieved 75% sensitivity with 100% specificity. Conclusions: DL-based isotropic 3D sequences provide high diagnostic accuracy for glenoid labral pathology while reducing scan time by 75%. Combined T1 and PD-FS protocols optimize performance. These findings support selective implementation of DL-accelerated 3D protocols in shoulder MR arthrography, particularly for labral assessment, while acknowledging that conventional protocols may remain preferable in specific clinical scenarios.

Authors

Institutions

Publication Details

Journal
Osteology
Published
2026-02-27
DOI
https://doi.org/10.3390/osteology6010004
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Deep Learning-Driven MR Arthrography of the Shoulder: Compressed 3D in Comparison to Standard FSE Sequences

Paolo Avanzi, Giuseppe Ocello, Giovanni Foti, Leonardo Monterubbiano et al.
Osteology
Shoulder Injury and Treatment
article

Accuracy of Deep Learning-Driven MR Arthrography of the Shoulder: Compressed 3D in Comparison to Standard FSE Sequences

Paolo Avanzi, Giuseppe Ocello, Giovanni Foti, Leonardo Monterubbiano, Flavio Spoto, Gianluca Tripodi
article en

Abstract

Background/Objectives: Magnetic resonance arthrography is the reference standard for evaluating glenoid labral lesions. Deep learning (DL) reconstruction algorithms may accelerate 3D acquisitions while maintaining image quality. This study assesses the diagnostic accuracy of DL-based isotropic 3D MR imaging for detecting glenoid labral lesions. Methods: This prospective study included 128 consecutive patients (79 men, 49 women; mean age 38.4 years) undergoing shoulder MR arthrography between June 2023 and April 2025. DL-based 3D sequences (acquisition time: 3:26) were compared with conventional multiplanar TSE and PD-FS sequences (acquisition time: 24–28 min). Two independent radiologists assessed glenoid labral lesions, bone marrow edema, and rotator cuff abnormalities using a four-point Likert scale. Sensitivity, specificity, and interobserver agreement were calculated. Results: DL-based 3D sequences demonstrated 94.7–95.1% sensitivity and 100% specificity for glenoid labral lesions, with excellent interobserver agreement (κ = 0.812). The area under the ROC curve was 0.894. Combined 3D protocols (T1 + PD-FS) showed superior accuracy (97.8%) compared to single sequences (90.5%, p = 0.012). For bone marrow edema, sensitivity was 82.9% with 100% specificity. Rotator cuff evaluation achieved 75% sensitivity with 100% specificity. Conclusions: DL-based isotropic 3D sequences provide high diagnostic accuracy for glenoid labral pathology while reducing scan time by 75%. Combined T1 and PD-FS protocols optimize performance. These findings support selective implementation of DL-accelerated 3D protocols in shoulder MR arthrography, particularly for labral assessment, while acknowledging that conventional protocols may remain preferable in specific clinical scenarios.

OsteologyVol. 6(1)
Ospedale Sacro Cuore Don Calabria (IT), Azienda Ospedaliera Universitaria Policlinico "G. Martino" (IT)
Quality Education
Openalex Percentile: Top 41%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.