Beyond tree cover: Vertical canopy structure is associated with the cooling impact of pocket parks in Mediterranean cities

As cities continue to densify, opportunities to introduce green areas decrease. Small urban green spaces, such as pocket parks, often represent the only remaining non-built-up areas within compact urban fabrics. Through shading, evapotranspiration, and the enhancement of air circulation, these spaces can provide microclimatic benefits; yet the cooling capacity of pocket parks and the role of their internal forest structure remain insufficiently explored. This study quantifies the association between forest structure, configuration, and species composition of urban pocket parks and morning cooling performance during a heat wave in the city of Barcelona, Spain. Moving beyond the conventional emphasis on tree canopy cover alone, the role of vertical structure of 627 urban trees was investigated. Five cooling indices—Park Cooling Distance (PCD), Park Cooling Area (PCA), Park Cooling Efficiency (PCE), Park Cooling Intensity (PCI), and Park Cooling Gradient (PCG)—were used to evaluate 18 pocket parks in densely built-up areas of the city. Statistical analyses assessed relationships between internal park characteristics and cooling performance, identifying the structural configurations with the strongest association. Results showed an average PCD of 55.8 m, PCA of 1.44 ha, PCE of 7.9, PCI of 1.2 °C, and PCG of 0.02 °C∙m⁻¹ in the studied pocket parks. Tree height, tree density, percentage of tree cover, and vertical structural variability were significantly correlated with PCE, PCI, and PCG, whereas no significant relationships were observed with PCD. The pocket parks exhibiting the strongest cooling performance association shared distinct structural characteristics, i.e., dense (>150 trees∙ha -1 ), predominantly monospecific trees concentrated in the upper canopy layer (>8.6 m) and were characterized by high canopy cover (>86%). These findings reveal that internal tree structure correlates to pocket park cooling performance. Design and management-oriented actions, focused on forest structure, may significantly enhance urban cooling and thermal comfort, contributing to climate adaptation strategies in compact urban environments. • High-performing pocket parks combine dense plantings, wide crowns, and continuous canopy • PPs are associated with a measurable differences in morning LST patterns • Smaller green spaces show higher cooling efficiency per unit area than larger parks • Tree height, density, and canopy cover are consistently related with cooling indices • High canopy cover in upper tree layers and low crown ratios are related to cooling • Design benchmarks suggest ≥150 trees/ha and canopy heights above 8.6 m

Authors

Institutions

Publication Details

Journal
Urban forestry & urban greening
Published
2026-02-27
DOI
https://doi.org/10.1016/j.ufug.2026.129371
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beyond tree cover: Vertical canopy structure is associated with the cooling impact of pocket parks in Mediterranean cities

Rocco Pace, Vittorio Garfì, Matilda van den Bosch, Elena Di Pirro et al.
Urban forestry & urban greening
Urban Heat Island Mitigation
article

Beyond tree cover: Vertical canopy structure is associated with the cooling impact of pocket parks in Mediterranean cities

Rocco Pace, Vittorio Garfì, Matilda van den Bosch, Elena Di Pirro, Eduardo Antenucci, Bruno Lasserre, Marco Marchetti
article en

Abstract

As cities continue to densify, opportunities to introduce green areas decrease. Small urban green spaces, such as pocket parks, often represent the only remaining non-built-up areas within compact urban fabrics. Through shading, evapotranspiration, and the enhancement of air circulation, these spaces can provide microclimatic benefits; yet the cooling capacity of pocket parks and the role of their internal forest structure remain insufficiently explored. This study quantifies the association between forest structure, configuration, and species composition of urban pocket parks and morning cooling performance during a heat wave in the city of Barcelona, Spain. Moving beyond the conventional emphasis on tree canopy cover alone, the role of vertical structure of 627 urban trees was investigated. Five cooling indices—Park Cooling Distance (PCD), Park Cooling Area (PCA), Park Cooling Efficiency (PCE), Park Cooling Intensity (PCI), and Park Cooling Gradient (PCG)—were used to evaluate 18 pocket parks in densely built-up areas of the city. Statistical analyses assessed relationships between internal park characteristics and cooling performance, identifying the structural configurations with the strongest association. Results showed an average PCD of 55.8 m, PCA of 1.44 ha, PCE of 7.9, PCI of 1.2 °C, and PCG of 0.02 °C∙m⁻¹ in the studied pocket parks. Tree height, tree density, percentage of tree cover, and vertical structural variability were significantly correlated with PCE, PCI, and PCG, whereas no significant relationships were observed with PCD. The pocket parks exhibiting the strongest cooling performance association shared distinct structural characteristics, i.e., dense (>150 trees∙ha -1 ), predominantly monospecific trees concentrated in the upper canopy layer (>8.6 m) and were characterized by high canopy cover (>86%). These findings reveal that internal tree structure correlates to pocket park cooling performance. Design and management-oriented actions, focused on forest structure, may significantly enhance urban cooling and thermal comfort, contributing to climate adaptation strategies in compact urban environments. • High-performing pocket parks combine dense plantings, wide crowns, and continuous canopy • PPs are associated with a measurable differences in morning LST patterns • Smaller green spaces show higher cooling efficiency per unit area than larger parks • Tree height, density, and canopy cover are consistently related with cooling indices • High canopy cover in upper tree layers and low crown ratios are related to cooling • Design benchmarks suggest ≥150 trees/ha and canopy heights above 8.6 m

Urban forestry & urban greeningVol. 119
University of Molise (IT), Eurac Research (IT), University of British Columbia (CA), Universitat Pompeu Fabra (ES), European Forest Institute (FI), Barcelona Institute for Global Health (ES), Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública (ES), Sapienza University of Rome (IT)
Climate action
Openalex Percentile: Top 49%
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.