Comparative Analysis of Enteric Methane Emissions in Lactating Holstein Cows Using the GreenFeed Monitoring System and the Sniffer Method

This study aimed to evaluate two different spot-sampling methods—the sniffer-based method (SB) and the GreenFeed system (GF)—for estimating enteric methane (CH<sub>4</sub>) emissions in dairy cows. Specifically, this study was performed to determine whether the SB using a gas hood system could serve as an acceptable alternative to the GF under practical on-farm conditions. A total of 24 lactating Holstein cows were used across three experimental phases (n = 24). CH<sub>4</sub> emissions were measured eight times over four consecutive days in each phase, with measurements taken twice per phase using both the GF and SB. CH<sub>4</sub> emissions from the SB were estimated by applying the CH<sub>4</sub>-to-carbon dioxide ratio to a previously validated prediction equation. Results showed that the GF tended to report higher CH<sub>4</sub> emissions (312.9 ± 56.50 g/d) compared to the SB (297.1 ± 61.83 g/d). Bland–Altman analysis showed acceptable agreement between methods, with a bias of 15.78 g/d and 95% limits of agreement ranging from –96.12 to 127.68 g/d, corresponding to 7.1% of the total range. For the CH<sub>4</sub>-to-carbon dioxide ratio, the SB produced consistently higher values (0.077 ± 0.012) than the GF (0.064 ± 0.011). Bland–Altman analysis for the CH<sub>4</sub>-to-carbon dioxide ratio indicated a small mean bias (–0.012) and minimal proportional deviation (21.3%). Variance homogeneity testing using the Brown-Forsythe test indicated no significant method-dependent differences in CH<sub>4</sub> emission variability across experimental phases (<italic>p</italic> = 0.104). Phase-specific performance of the SB showed acceptable agreement with the GF, with mean absolute percentage errors ranging from 11.57% to 19.20% and confidence rates between 80.80% and 88.43% across phases. In summary, the SB provided CH<sub>4</sub> estimates comparable to those from the GF across all experimental phases. Given its advantages such as portability, flexible installation, and low operational cost, the SB represents a feasible and accessible alternative for on-farm quantification of CH<sub>4 </sub>emissions in dairy cows. Together, these findings indicate that the SB provides acceptable estimates of CH<sub>4</sub> emissions from lactating Holstein cows under on-farm conditions, making it a feasible on-farm measurement method alternative to the GF.

Authors

Publication Details

Journal
Journal of Animal Science and Technology
Published
2026-02-25
DOI
https://doi.org/10.5187/jast.2500439
Primary Topic
Ruminant Nutrition and Digestive Physiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Enteric Methane Emissions in Lactating Holstein Cows Using the GreenFeed Monitoring System and the Sniffer Method

Sungdae Lee, Wonseob Kim, Huseong Lee, Taketo Obitsu et al.
Journal of Animal Science and Technology
Ruminant Nutrition and Digestive Physiology
article

Comparative Analysis of Enteric Methane Emissions in Lactating Holstein Cows Using the GreenFeed Monitoring System and the Sniffer Method

Sungdae Lee, Wonseob Kim, Huseong Lee, Taketo Obitsu, SangGun Roh, Honggu Lee, Jaesung Lee, Kyunghwan Oh, Yoorae Kim, Janghoon Jo, Yubeen Cho, Eunjoong Kim
article en

Abstract

This study aimed to evaluate two different spot-sampling methods—the sniffer-based method (SB) and the GreenFeed system (GF)—for estimating enteric methane (CH<sub>4</sub>) emissions in dairy cows. Specifically, this study was performed to determine whether the SB using a gas hood system could serve as an acceptable alternative to the GF under practical on-farm conditions. A total of 24 lactating Holstein cows were used across three experimental phases (n = 24). CH<sub>4</sub> emissions were measured eight times over four consecutive days in each phase, with measurements taken twice per phase using both the GF and SB. CH<sub>4</sub> emissions from the SB were estimated by applying the CH<sub>4</sub>-to-carbon dioxide ratio to a previously validated prediction equation. Results showed that the GF tended to report higher CH<sub>4</sub> emissions (312.9 ± 56.50 g/d) compared to the SB (297.1 ± 61.83 g/d). Bland–Altman analysis showed acceptable agreement between methods, with a bias of 15.78 g/d and 95% limits of agreement ranging from –96.12 to 127.68 g/d, corresponding to 7.1% of the total range. For the CH<sub>4</sub>-to-carbon dioxide ratio, the SB produced consistently higher values (0.077 ± 0.012) than the GF (0.064 ± 0.011). Bland–Altman analysis for the CH<sub>4</sub>-to-carbon dioxide ratio indicated a small mean bias (–0.012) and minimal proportional deviation (21.3%). Variance homogeneity testing using the Brown-Forsythe test indicated no significant method-dependent differences in CH<sub>4</sub> emission variability across experimental phases (<italic>p</italic> = 0.104). Phase-specific performance of the SB showed acceptable agreement with the GF, with mean absolute percentage errors ranging from 11.57% to 19.20% and confidence rates between 80.80% and 88.43% across phases. In summary, the SB provided CH<sub>4</sub> estimates comparable to those from the GF across all experimental phases. Given its advantages such as portability, flexible installation, and low operational cost, the SB represents a feasible and accessible alternative for on-farm quantification of CH<sub>4 </sub>emissions in dairy cows. Together, these findings indicate that the SB provides acceptable estimates of CH<sub>4</sub> emissions from lactating Holstein cows under on-farm conditions, making it a feasible on-farm measurement method alternative to the GF.

Journal of Animal Science and Technology
Openalex Percentile: Top 40%
Ruminant Nutrition and Digestive Physiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.