Should We Worry About the Inter-Implant Gap in the Tibia? A Finite Element Analysis of Revision TKA and Distal Plating

<i>Background and Objectives</i>: The management of periprosthetic tibial fractures distal to revision Total Knee Arthroplasty (TKA) presents a biomechanical challenge, often requiring extramedullary locking plates when long stems preclude nailing. While in femoral fractures the gap between the stem and plate is a well-documented stress riser, requiring implant overlap to prevent an inter-implant fracture, this specific biomechanical scenario has not been studied in the tibia, and it remains unclear if the femoral dogma of mandatory overlap applies to the straight, centrically loaded tibial anatomy. This study utilized Finite Element Analysis (FEA) to evaluate stress distribution in the tibial inter-implant gap. <i>Materials and Methods:</i> A comparative FEA was performed using a validated standardized tibia model simulating a healed distal fracture. Two cemented revision TKA constructs (50 mm and 80 mm stems) were modeled. These were paired with medial locking plates of varying lengths (10, 12, and 14 holes) to create different inter-implant distances. Eight distinct configurations, including non-plated controls, were subjected to physiological axial compression and three-point bending. Outcome measures included von Mises stress and total displacement. <i>Results:</i> The analysis revealed no significant stress concentration in the bone within the inter-implant zone across all plated models, regardless of the gap size. Instead, the addition of plates universally reduced bone stress compared to controls, effectively transferring load to the fixation hardware. Peak stresses were consistently observed in the proximal locking screws rather than the bone gap. The longest plates (14 holes) offered superior construct rigidity and stress distribution. <i>Conclusions</i>: Under the conditions evaluated in this preclinical finite element model, the tibia does not exhibit a biomechanical requirement for implant overlap to prevent stress risers. Our findings suggest that extramedullary fixation with the longest available anatomical locking plate represents a biomechanically plausible strategy for these fractures, even if an inter-implant gap remains.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-02-27
DOI
https://doi.org/10.3390/medicina62030450
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Should We Worry About the Inter-Implant Gap in the Tibia? A Finite Element Analysis of Revision TKA and Distal Plating

Renato Caravellos Glória, Pedro José Labronici, Anderson Freitas
Medicina
Total Knee Arthroplasty Outcomes
article

Should We Worry About the Inter-Implant Gap in the Tibia? A Finite Element Analysis of Revision TKA and Distal Plating

Renato Caravellos Glória, Pedro José Labronici, Anderson Freitas
article en

Abstract

<i>Background and Objectives</i>: The management of periprosthetic tibial fractures distal to revision Total Knee Arthroplasty (TKA) presents a biomechanical challenge, often requiring extramedullary locking plates when long stems preclude nailing. While in femoral fractures the gap between the stem and plate is a well-documented stress riser, requiring implant overlap to prevent an inter-implant fracture, this specific biomechanical scenario has not been studied in the tibia, and it remains unclear if the femoral dogma of mandatory overlap applies to the straight, centrically loaded tibial anatomy. This study utilized Finite Element Analysis (FEA) to evaluate stress distribution in the tibial inter-implant gap. <i>Materials and Methods:</i> A comparative FEA was performed using a validated standardized tibia model simulating a healed distal fracture. Two cemented revision TKA constructs (50 mm and 80 mm stems) were modeled. These were paired with medial locking plates of varying lengths (10, 12, and 14 holes) to create different inter-implant distances. Eight distinct configurations, including non-plated controls, were subjected to physiological axial compression and three-point bending. Outcome measures included von Mises stress and total displacement. <i>Results:</i> The analysis revealed no significant stress concentration in the bone within the inter-implant zone across all plated models, regardless of the gap size. Instead, the addition of plates universally reduced bone stress compared to controls, effectively transferring load to the fixation hardware. Peak stresses were consistently observed in the proximal locking screws rather than the bone gap. The longest plates (14 holes) offered superior construct rigidity and stress distribution. <i>Conclusions</i>: Under the conditions evaluated in this preclinical finite element model, the tibia does not exhibit a biomechanical requirement for implant overlap to prevent stress risers. Our findings suggest that extramedullary fixation with the longest available anatomical locking plate represents a biomechanically plausible strategy for these fractures, even if an inter-implant gap remains.

MedicinaVol. 62(3)
Universidade Federal Fluminense (BR), Hospital São Vicente de Paulo (BR), Hospital São Vicente (BR), Hospital de Especialidades (MX), Instituto Nacional de Traumatologia e Ortopedia (BR)
Openalex Percentile: Top 41%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.