A pilot study of a novel portable mass spectrometer for rapid, simultaneous detection of multiple anesthetic drug concentrations

In the perioperative management of emergency animals, anesthetic drug-related toxicity and adverse effects pose substantial risks, and real-time quantification of anesthetic drug concentrations may provide an effective strategy for improving anesthetic safety. This study aimed to evaluate the feasibility and accuracy of a novel Cell portable mass spectrometer (MS) for the rapid detection of multiple anesthetic drug concentrations. Etomidate (ET, 1.5 mg/kg), rocuronium bromide (ROC, 5 mg/kg), and lidocaine (LID, 2 mg/kg) were administered, and plasma samples from rats were analyzed using the Cell portable MS and compared with results obtained by high-performance liquid chromatography with mass spectrometry (HPLC-MS). The Cell portable MS enabled simultaneous quantitative analysis of all three anesthetic drugs within 4.5 min and demonstrated good linearity across detection ranges. The regression equations were y = 0.01496x + 0.3136 for ET (<i>R</i> <sup>2</sup> = 0.997), y = 1,356.03x + 12,785.42 for ROC (<i>R</i> <sup>2</sup> = 0.991), and y = 0.01459x + 0.0067 for LID (<i>R</i> <sup>2</sup> = 0.999). Pearson correlation analysis revealed strong correlations between Cell portable MS and HPLC-MS measurements for all three drugs (ET: <i>r</i> = 0.9666; ROC: <i>r</i> = 0.9858; LID: <i>r</i> = 0.9937; all <i>p</i> < 0.0001). Bland-Altman analysis showed small mean biases, with most data points falling within the 95% limits of agreement and no proportional bias observed. Overall, the Cell portable MS demonstrated good quantitative agreement with conventional HPLC-MS for rapid, simultaneous measurement of multiple anesthetic drug concentrations, supporting its potential for real-time anesthetic drug toxicity monitoring and individualized dosing, particularly in emergency settings.

Authors

Institutions

Publication Details

Journal
Frontiers in Veterinary Science
Published
2026-02-27
DOI
https://doi.org/10.3389/fvets.2026.1776326
Primary Topic
Veterinary Pharmacology and Anesthesia
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A pilot study of a novel portable mass spectrometer for rapid, simultaneous detection of multiple anesthetic drug concentrations

Xiaoyu Xie, Xiaoxiao Li, Wensheng Zhang
Frontiers in Veterinary Science
Veterinary Pharmacology and Anesthesia
article

A pilot study of a novel portable mass spectrometer for rapid, simultaneous detection of multiple anesthetic drug concentrations

Xiaoyu Xie, Xiaoxiao Li, Wensheng Zhang
article en

Abstract

In the perioperative management of emergency animals, anesthetic drug-related toxicity and adverse effects pose substantial risks, and real-time quantification of anesthetic drug concentrations may provide an effective strategy for improving anesthetic safety. This study aimed to evaluate the feasibility and accuracy of a novel Cell portable mass spectrometer (MS) for the rapid detection of multiple anesthetic drug concentrations. Etomidate (ET, 1.5 mg/kg), rocuronium bromide (ROC, 5 mg/kg), and lidocaine (LID, 2 mg/kg) were administered, and plasma samples from rats were analyzed using the Cell portable MS and compared with results obtained by high-performance liquid chromatography with mass spectrometry (HPLC-MS). The Cell portable MS enabled simultaneous quantitative analysis of all three anesthetic drugs within 4.5 min and demonstrated good linearity across detection ranges. The regression equations were y = 0.01496x + 0.3136 for ET (<i>R</i> <sup>2</sup> = 0.997), y = 1,356.03x + 12,785.42 for ROC (<i>R</i> <sup>2</sup> = 0.991), and y = 0.01459x + 0.0067 for LID (<i>R</i> <sup>2</sup> = 0.999). Pearson correlation analysis revealed strong correlations between Cell portable MS and HPLC-MS measurements for all three drugs (ET: <i>r</i> = 0.9666; ROC: <i>r</i> = 0.9858; LID: <i>r</i> = 0.9937; all <i>p</i> < 0.0001). Bland-Altman analysis showed small mean biases, with most data points falling within the 95% limits of agreement and no proportional bias observed. Overall, the Cell portable MS demonstrated good quantitative agreement with conventional HPLC-MS for rapid, simultaneous measurement of multiple anesthetic drug concentrations, supporting its potential for real-time anesthetic drug toxicity monitoring and individualized dosing, particularly in emergency settings.

Frontiers in Veterinary ScienceVol. 13
Sichuan University (CN), West China Hospital of Sichuan University (CN)
China Postdoctoral Science Foundation, Natural Science Foundation of Sichuan Province, Young Scientists Fund
Good health and well-being
Openalex Percentile: Top 40%
Veterinary Pharmacology and Anesthesia
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.