Development and Validation of an Interface Between the BIANCA Biophysical Model and Geant4 for Particle Therapy

<b>Objectives</b>: The main aim of this study consists of testing the consistency and reliability of the BIANCA (BIophysical ANalysis of Cell death and chromosome Aberrations) biophysical model across different radiation transport codes in the framework of cancer ion-therapy research. <b>Methods</b>: Spread-Out Bragg Peak (SOBP) profiles for protons, helium ions and carbon ions were simulated at three different depth ranges (2-3 cm, 5-8 cm, and 10-15 cm) applying two radiation transport codes, FLUKA and Geant4. While BIANCA has been interfaced to FLUKA in a previous work, an interface with Geant4 was purposely developed in this work. Cell survival along all considered SOBP profiles was predicted by BIANCA for two cell lines with very different radiosensitivities: Squamous Cell Carcinoma (SCC), with α/β = 12.68 Gy, and chordoma, with α/β = 2.37 Gy. The agreement between the predictions obtained from the two approaches was quantitatively evaluated by means of Root Mean Square Error (RMSE) and Gamma Index analysis, both for physical dose distributions and for cell survival predictions. <b>Results</b>: The comparison between FLUKA and Geant4 simulations demonstrated good agreement. The Gamma Index analysis yielded passing rates exceeding 94.9% for physical dose profiles (criteria: 3%/2 mm) and 96.0% for cell survival probabilities (criteria: 2%/2 mm) across all considered ion species (protons, He, C) and depths. Root Mean Square Error (RMSE) analysis confirmed average discrepancies below 2.5% for physical dose and 1% for biological survival. <b>Conclusions</b>: This study shows that the BIANCA model can be applied to predict cell killing along hadron therapy beams when interfaced both with FLUKA and with Geant4. Furthermore, the successful implementation of the interface with Geant4 expands the accessibility and applicability of BIANCA, paving the way for its future integration into different transport codes and/or treatment planning systems.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2026-02-27
DOI
https://doi.org/10.3390/biomedicines14030542
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of an Interface Between the BIANCA Biophysical Model and Geant4 for Particle Therapy

F. Ballarini, Ricardo Luis Ramos, Mario Pietro Carante, Alice Casali et al.
Biomedicines
Radiation Therapy and Dosimetry
article

Development and Validation of an Interface Between the BIANCA Biophysical Model and Geant4 for Particle Therapy

F. Ballarini, Ricardo Luis Ramos, Mario Pietro Carante, Alice Casali, Ezequiel Canay, Aurora Madonnini
article en

Abstract

<b>Objectives</b>: The main aim of this study consists of testing the consistency and reliability of the BIANCA (BIophysical ANalysis of Cell death and chromosome Aberrations) biophysical model across different radiation transport codes in the framework of cancer ion-therapy research. <b>Methods</b>: Spread-Out Bragg Peak (SOBP) profiles for protons, helium ions and carbon ions were simulated at three different depth ranges (2-3 cm, 5-8 cm, and 10-15 cm) applying two radiation transport codes, FLUKA and Geant4. While BIANCA has been interfaced to FLUKA in a previous work, an interface with Geant4 was purposely developed in this work. Cell survival along all considered SOBP profiles was predicted by BIANCA for two cell lines with very different radiosensitivities: Squamous Cell Carcinoma (SCC), with α/β = 12.68 Gy, and chordoma, with α/β = 2.37 Gy. The agreement between the predictions obtained from the two approaches was quantitatively evaluated by means of Root Mean Square Error (RMSE) and Gamma Index analysis, both for physical dose distributions and for cell survival predictions. <b>Results</b>: The comparison between FLUKA and Geant4 simulations demonstrated good agreement. The Gamma Index analysis yielded passing rates exceeding 94.9% for physical dose profiles (criteria: 3%/2 mm) and 96.0% for cell survival probabilities (criteria: 2%/2 mm) across all considered ion species (protons, He, C) and depths. Root Mean Square Error (RMSE) analysis confirmed average discrepancies below 2.5% for physical dose and 1% for biological survival. <b>Conclusions</b>: This study shows that the BIANCA model can be applied to predict cell killing along hadron therapy beams when interfaced both with FLUKA and with Geant4. Furthermore, the successful implementation of the interface with Geant4 expands the accessibility and applicability of BIANCA, paving the way for its future integration into different transport codes and/or treatment planning systems.

BiomedicinesVol. 14(3)
National University of General San Martín (AR), University of Pavia (IT), National Institute of Industrial Technology (AR), Istituto Nazionale di Fisica Nucleare, Sezione di Pavia (IT), Comisión Nacional de Energía Atómica (AR)
Openalex Percentile: Top 41%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.