Outcomes and complications of exposed Kirschner wire f ixation for metacarpal fractures: a retrospective study

<div class="page" title="Page 1"> <div class="layoutArea"> <div class="column"> <p><strong>Aim </strong>Metacarpal fractures are common hand injuries, frequently treated with closed reduction and internal fixation (CRIF) using Kirschner wires (K-wires). While exposed K-wires allow for simple hardware removal and early mobilization, their use is traditionally associated with a higher risk of pin tract infections. There is a lack of studies focusing exclusively on exposed K-wires in metacarpal fractures.</p> <p><strong>Methods</strong><strong> </strong>It was retrospectively reviewed 134 patients who underwent CRIF with exposed K-wires for metacarpal fractures between January 2023 and March 2024. After applying inclusion and exclusion criteria, 118 patients were analyzed. Demographics, fracture characteristics, complications, and follow-up data were collected. Functional outcomes were assessed using the QuickDASH and the Michigan Hand Outcomes Questionnaire (MHQ) before hardware removal.</p> <p><strong>Results</strong><strong> </strong>Most patients were male, 88 (75%), with a mean age of 39.3 years. The little finger was the most frequently injured, 71 (60%). In 102 (86%) cases, a single metacarpal fracture was observed. The average number of wires used was 1.7, and hardware was removed after a mean of 40.1 days. The rate of pin tract infection was <4%, all classified as superficial and managed conservatively. Only one case required reoperation due to secondary displacement. The mean QuickDASH score was 25, and the average MHQ score was 70.15, indicating overall good functional and patient-reported outcomes.</p> <p><strong>Conclusion</strong><strong> </strong>Exposed K-wire fixation for metacarpal fractures appears safe and reliable, with low complication rates and favorable patient-reported outcomes, supporting its use in outpatient pathways without compromising safety.</p> </div> </div> </div>

Authors

Institutions

Publication Details

Journal
Medicinski Glasnik
Published
2026-02-27
DOI
https://doi.org/10.17392/2015-23-01
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outcomes and complications of exposed Kirschner wire f ixation for metacarpal fractures: a retrospective study

Alessandro El Motassime, Silvia Pietramala, Alessio GRECO, Lorenzo Rocchi et al.
Medicinski Glasnik
Orthopedic Surgery and Rehabilitation
article

Outcomes and complications of exposed Kirschner wire f ixation for metacarpal fractures: a retrospective study

Alessandro El Motassime, Silvia Pietramala, Alessio GRECO, Lorenzo Rocchi, Camillo Fulchignoni, Andrea Cruciani
article en

Abstract

<div class="page" title="Page 1"> <div class="layoutArea"> <div class="column"> <p><strong>Aim </strong>Metacarpal fractures are common hand injuries, frequently treated with closed reduction and internal fixation (CRIF) using Kirschner wires (K-wires). While exposed K-wires allow for simple hardware removal and early mobilization, their use is traditionally associated with a higher risk of pin tract infections. There is a lack of studies focusing exclusively on exposed K-wires in metacarpal fractures.</p> <p><strong>Methods</strong><strong> </strong>It was retrospectively reviewed 134 patients who underwent CRIF with exposed K-wires for metacarpal fractures between January 2023 and March 2024. After applying inclusion and exclusion criteria, 118 patients were analyzed. Demographics, fracture characteristics, complications, and follow-up data were collected. Functional outcomes were assessed using the QuickDASH and the Michigan Hand Outcomes Questionnaire (MHQ) before hardware removal.</p> <p><strong>Results</strong><strong> </strong>Most patients were male, 88 (75%), with a mean age of 39.3 years. The little finger was the most frequently injured, 71 (60%). In 102 (86%) cases, a single metacarpal fracture was observed. The average number of wires used was 1.7, and hardware was removed after a mean of 40.1 days. The rate of pin tract infection was <4%, all classified as superficial and managed conservatively. Only one case required reoperation due to secondary displacement. The mean QuickDASH score was 25, and the average MHQ score was 70.15, indicating overall good functional and patient-reported outcomes.</p> <p><strong>Conclusion</strong><strong> </strong>Exposed K-wire fixation for metacarpal fractures appears safe and reliable, with low complication rates and favorable patient-reported outcomes, supporting its use in outpatient pathways without compromising safety.</p> </div> </div> </div>

Medicinski GlasnikVol. 23(1)
Università Cattolica del Sacro Cuore (IT), Agostino Gemelli University Polyclinic (IT)
Reduced inequalities
Openalex Percentile: Top 41%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.