A Technique for Accurately Identifying and Harvesting the Extensor Indicis Proprius for Tendon Transfer

The extensor indicis proprius (EIP) is commonly used as a donor for tendon transfers. It normally inserts on the ulnar aspect of the extensor hood with the extensor digitorum communis (EDC) to the index finger inserting on the radial aspect. Anatomical studies have reported variations in EIP anatomy with a 1%-1.5% incidence of EIP insertion onto the radial aspect of the extensor hood. In our experience with 60 EIP transfers over 18 years, we found the EIP to insert onto the radial aspect of the extensor hood in three patients (5%). This is higher than what has been reported in the literature. We confirm the EDC by identifying the juncturae tendinae connecting the index and long finger EDC. We review relevant literature and suggest technical tips to avoid accidentally harvesting the wrong tendon. <b>Level of Evidence:</b> Level V (Therapeutic).

Authors

Institutions

Publication Details

Journal
The Journal of Hand Surgery (Asian-Pacific Volume)
Published
2026-02-26
DOI
https://doi.org/10.1142/s2424835526970040
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Technique for Accurately Identifying and Harvesting the Extensor Indicis Proprius for Tendon Transfer

Sunil M. Thirkannad, Rouzbeh K. Kordestani, Natalie RODRIQUEZ
The Journal of Hand Surgery (Asian-Pacific Volume)
Orthopedic Surgery and Rehabilitation
article

A Technique for Accurately Identifying and Harvesting the Extensor Indicis Proprius for Tendon Transfer

Sunil M. Thirkannad, Rouzbeh K. Kordestani, Natalie RODRIQUEZ
article en

Abstract

The extensor indicis proprius (EIP) is commonly used as a donor for tendon transfers. It normally inserts on the ulnar aspect of the extensor hood with the extensor digitorum communis (EDC) to the index finger inserting on the radial aspect. Anatomical studies have reported variations in EIP anatomy with a 1%-1.5% incidence of EIP insertion onto the radial aspect of the extensor hood. In our experience with 60 EIP transfers over 18 years, we found the EIP to insert onto the radial aspect of the extensor hood in three patients (5%). This is higher than what has been reported in the literature. We confirm the EDC by identifying the juncturae tendinae connecting the index and long finger EDC. We review relevant literature and suggest technical tips to avoid accidentally harvesting the wrong tendon. <b>Level of Evidence:</b> Level V (Therapeutic).

The Journal of Hand Surgery (Asian-Pacific Volume)
University of Louisville (US), Christine M. Kleinert Institute (US)
Openalex Percentile: Top 41%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.