Automatic sleep scoring for real-time monitoring and stimulation in individuals with and without sleep apnea

Digital therapeutics, enabled by advanced machine learning algorithms and medical wearable devices, offer a promising approach to streamline diagnostics and improve access to healthcare. Within this framework, automatic sleep scoring can provide accurate and efficient sleep analysis from electrophysiological signals recorded with wearable sensors, such as electroencephalography (EEG). However, the optimal configuration and temporal dynamics of automatic sleep scoring systems remain unclear, especially concerning their performance across different population samples. This study systematically investigates the impact of: (1) electrode setup, (2) temporal scope, and (3) population characteristics on the performance of automatic sleep scoring algorithms. Utilizing a convolutional neural network (CNN), we analyzed various electrode configurations and temporal dynamics using datasets comprising both healthy participants and individuals with sleep apnea. Our findings reveal that sleep scoring based on a single frontal EEG channel demonstrates reliable congruency with human expert scorers, with minimal improvement observed with additional sensors. Moreover, we demonstrate that real-time sleep scoring can be achieved with comparable accuracy to offline methods, which rely on past and future information to classify a window of interest. Remarkably, a notable reduction in decoding accuracy is observed for individuals with sleep apnea compared to healthy participants, highlighting the challenges inherent in accurately assessing sleep stages in clinical populations. Digital solutions for automatic sleep scoring hold promise for facilitating timely diagnoses and personalized treatment plans, with applications extending beyond sleep analysis to include closed-loop neurostimulation interventions. Our findings provide valuable insights into the complexities of automatic sleep scoring and offer considerations for the development of effective and efficient sleep assessment tools in both clinical and research settings.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2026-02-27
DOI
https://doi.org/10.1016/j.compbiomed.2026.111560
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic sleep scoring for real-time monitoring and stimulation in individuals with and without sleep apnea

Martín Esparza-Iaizzo, Jens G. Klinzing, Eduardo López‐Larraz, Luis Montesano et al.
Computers in Biology and Medicine
Obstructive Sleep Apnea Research
article

Automatic sleep scoring for real-time monitoring and stimulation in individuals with and without sleep apnea

Martín Esparza-Iaizzo, Jens G. Klinzing, Eduardo López‐Larraz, Luis Montesano, María Sierra-Torralba, Javier Minguez
article en

Abstract

Digital therapeutics, enabled by advanced machine learning algorithms and medical wearable devices, offer a promising approach to streamline diagnostics and improve access to healthcare. Within this framework, automatic sleep scoring can provide accurate and efficient sleep analysis from electrophysiological signals recorded with wearable sensors, such as electroencephalography (EEG). However, the optimal configuration and temporal dynamics of automatic sleep scoring systems remain unclear, especially concerning their performance across different population samples. This study systematically investigates the impact of: (1) electrode setup, (2) temporal scope, and (3) population characteristics on the performance of automatic sleep scoring algorithms. Utilizing a convolutional neural network (CNN), we analyzed various electrode configurations and temporal dynamics using datasets comprising both healthy participants and individuals with sleep apnea. Our findings reveal that sleep scoring based on a single frontal EEG channel demonstrates reliable congruency with human expert scorers, with minimal improvement observed with additional sensors. Moreover, we demonstrate that real-time sleep scoring can be achieved with comparable accuracy to offline methods, which rely on past and future information to classify a window of interest. Remarkably, a notable reduction in decoding accuracy is observed for individuals with sleep apnea compared to healthy participants, highlighting the challenges inherent in accurately assessing sleep stages in clinical populations. Digital solutions for automatic sleep scoring hold promise for facilitating timely diagnoses and personalized treatment plans, with applications extending beyond sleep analysis to include closed-loop neurostimulation interventions. Our findings provide valuable insights into the complexities of automatic sleep scoring and offer considerations for the development of effective and efficient sleep assessment tools in both clinical and research settings.

Computers in Biology and MedicineVol. 205
Universitat Pompeu Fabra (ES), Universidad de Zaragoza (ES), Euskadiko Parke Teknologikoa (ES), Instituto Tecnológico de Aragón (ES)
Openalex Percentile: Top 40%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.