Temporal Patterns of Skin-Fixed Depth Electrodes During Stereotactic Electroencephalography Recording

Introduction: Stereotactic electroencephalography (SEEG) is increasingly used to evaluate patients with refractory epilepsy. While anchor bolts are widely used for depth electrode fixation, their lack of insurance coverage or technical limitations may necessitate alternative methods, such as fixation to the skin. Few studies have investigated how fixation methods affect electrode dislocation during recording. Methods: To clarify the time-dependent pattern of skin-fixed electrode dislocation, depth electrode dislocation during recording was evaluated in 41 electrodes from four patients with anchor bolt fixation and 66 electrodes from five patients with skin fixation. Results: Twenty-nine electrodes in the anchor bolt group and 45 electrodes in the skin fixation group were targeted to the anterior temporal or perisylvian regions. The mean cumulative migration in longitudinal direction during recording was 4.34 ± 2.43 mm in the skin fixation group compared to 0.16 ± 0.43 mm in the anchor bolt group (p < 0.0001). In the skin fixation group, the net migration during recording was -2.53 ± 2.20 mm, and the net migration from the original position was +0.37 ± 1.87 mm in the skin fixation group (negative values represent inward migration). Electrode migration was most prominent during the bilateral implantation procedure (+6.01 ± 3.48 mm). The mean electrode shift (lateral displacement) in the skin fixation group was 0.87 ± 0.68 mm. No migration-related complications were observed. Conclusion: Temporal pattern of skin-fixed depth electrode dislocation was evaluated in detail. Fixation to the skin carries a higher risk of electrode migration compared to anchor bolts. Although this rarely causes clinical complications, caution is warranted both for risk prevention and when interpreting anatomo-electrophysiological relationships.

Authors

Publication Details

Journal
Cureus
Published
2026-02-26
DOI
https://doi.org/10.7759/cureus.104348
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temporal Patterns of Skin-Fixed Depth Electrodes During Stereotactic Electroencephalography Recording

Yukihiro Yamao, Daisuke Yamada, Akio Ikeda, Ai Demura et al.
Cureus
Neuroscience and Neural Engineering
article

Temporal Patterns of Skin-Fixed Depth Electrodes During Stereotactic Electroencephalography Recording

Yukihiro Yamao, Daisuke Yamada, Akio Ikeda, Ai Demura, Yoshiki Arakawa, Masahiro Sawada, Riki Matsumoto, Takeshi Yoshida, Katsuya Kobayashi, Takayuki Kikuchi
article en

Abstract

Introduction: Stereotactic electroencephalography (SEEG) is increasingly used to evaluate patients with refractory epilepsy. While anchor bolts are widely used for depth electrode fixation, their lack of insurance coverage or technical limitations may necessitate alternative methods, such as fixation to the skin. Few studies have investigated how fixation methods affect electrode dislocation during recording. Methods: To clarify the time-dependent pattern of skin-fixed electrode dislocation, depth electrode dislocation during recording was evaluated in 41 electrodes from four patients with anchor bolt fixation and 66 electrodes from five patients with skin fixation. Results: Twenty-nine electrodes in the anchor bolt group and 45 electrodes in the skin fixation group were targeted to the anterior temporal or perisylvian regions. The mean cumulative migration in longitudinal direction during recording was 4.34 ± 2.43 mm in the skin fixation group compared to 0.16 ± 0.43 mm in the anchor bolt group (p < 0.0001). In the skin fixation group, the net migration during recording was -2.53 ± 2.20 mm, and the net migration from the original position was +0.37 ± 1.87 mm in the skin fixation group (negative values represent inward migration). Electrode migration was most prominent during the bilateral implantation procedure (+6.01 ± 3.48 mm). The mean electrode shift (lateral displacement) in the skin fixation group was 0.87 ± 0.68 mm. No migration-related complications were observed. Conclusion: Temporal pattern of skin-fixed depth electrode dislocation was evaluated in detail. Fixation to the skin carries a higher risk of electrode migration compared to anchor bolts. Although this rarely causes clinical complications, caution is warranted both for risk prevention and when interpreting anatomo-electrophysiological relationships.

Cureus
Openalex Percentile: Top 42%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.