Comparison of methods for detecting ciprofloxacin in pharmaceuticals and urine: UV–Vis spectrophotometry versus poly ([Mn(Chr)3]Cl2)/PGE voltammetry

Abstract Background Ciprofloxacin (Cpro) is a drug belonging to the fluoroquinolones class which can contribute to bacterial resistance due to its improper and overuse, and excretion in urine as unchanged. Therefore, continuous monitoring is required. In this work, voltammetric technique with pencil graphite electrode (PGE) modified by manganese(II)-chrysin complex ([Mn(Chr) 3 ]Cl 2 ) has been developed and its performance has been compared with the unmodified PGE working electrode and UV–Vis spectrophotometric method. Results Both the developed and UV–Vis spectrophotometric methods were calibrated using a series of standard solutions of Cpro with increasing concentration in the range of 1–250 µM. After calibrating the two methods, Cpro has been determined in two brands of pharmaceuticals, in urine samples, and in the presence of paracetamol. The values of dynamic range, LoD, and sensitivity for the developed method were 1–250 µM, 0.536 µM, and 0.148, respectively, whereas in UV–Vis spectrophotometric method the dynamic range, LoD, and sensitivity were 1–120 µM, 0.413 µM, and 0.025, respectively. Conclusion Based on slope value, dynamic range, and selectivity the developed method has better performance than UV–Vis spectrophotometric method. Graphical abstract

Authors

Institutions

Publication Details

Journal
Future Journal of Pharmaceutical Sciences
Published
2026-02-27
DOI
https://doi.org/10.1186/s43094-026-00948-1
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of methods for detecting ciprofloxacin in pharmaceuticals and urine: UV–Vis spectrophotometry versus poly ([Mn(Chr)3]Cl2)/PGE voltammetry

Belete Asefa Aragaw, Atakilt Abebe, Amare Benor, Minaleshewa Atlabachew et al.
Future Journal of Pharmaceutical Sciences
Antibiotics Pharmacokinetics and Efficacy
article

Comparison of methods for detecting ciprofloxacin in pharmaceuticals and urine: UV–Vis spectrophotometry versus poly ([Mn(Chr)3]Cl2)/PGE voltammetry

Belete Asefa Aragaw, Atakilt Abebe, Amare Benor, Minaleshewa Atlabachew, Abebaw Shitahun Ayicheh, Bamlaku Abebaw
article en

Abstract

Abstract Background Ciprofloxacin (Cpro) is a drug belonging to the fluoroquinolones class which can contribute to bacterial resistance due to its improper and overuse, and excretion in urine as unchanged. Therefore, continuous monitoring is required. In this work, voltammetric technique with pencil graphite electrode (PGE) modified by manganese(II)-chrysin complex ([Mn(Chr) 3 ]Cl 2 ) has been developed and its performance has been compared with the unmodified PGE working electrode and UV–Vis spectrophotometric method. Results Both the developed and UV–Vis spectrophotometric methods were calibrated using a series of standard solutions of Cpro with increasing concentration in the range of 1–250 µM. After calibrating the two methods, Cpro has been determined in two brands of pharmaceuticals, in urine samples, and in the presence of paracetamol. The values of dynamic range, LoD, and sensitivity for the developed method were 1–250 µM, 0.536 µM, and 0.148, respectively, whereas in UV–Vis spectrophotometric method the dynamic range, LoD, and sensitivity were 1–120 µM, 0.413 µM, and 0.025, respectively. Conclusion Based on slope value, dynamic range, and selectivity the developed method has better performance than UV–Vis spectrophotometric method. Graphical abstract

Future Journal of Pharmaceutical SciencesVol. 12(1)
Jinka University, Bahir Dar University (ET), Debre Markos University (ET)
Uppsala Universitet
Openalex Percentile: Top 41%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.