Aortic wall needle extraction: Difference between forceps and needle holder use

BackgroundWe investigated the difference in the extracted surfaces between extractions carried out using forceps and a needle holder, focusing on needle extraction manipulation for smaller needle-hole defects.MethodsIn this prospective observational study, we included patients who underwent aortic surgery at our Hospital between December 2023 and January 2025. Aortic wall samples were collected from the patients with acute type A aortic dissection (<i>n = </i>20) and thoracic aortic aneurysm (<i>n = </i>20). Two hundred needle holes were created in the samples from each disease type and randomized into two groups: the forceps (<i>n = </i>100) and needle holder (<i>n = </i>100) groups. The long axis, short axis, and area of needle-hole defects were measured and compared between the two groups.ResultsOverall, the long axis in the needle holder group was significantly shorter than that in the forceps group (forceps: 0.52 ± 0.18 vs. needle holder: 0.48 ± 0.12 mm, <i>P</i> = 0.036). The short axis was not significantly different between the groups (forceps: 0.26 ± 0.07 vs. needle holder: 0.25 ± 0.06 mm, <i>P</i> = 0.223). The defect area in the needle holder group was significantly smaller than that in the forceps group (forceps: 0.11 ± 0.06 vs. needle holder: 0.09 ± 0.03 mm2, <i>P</i> = 0.022). Acute aortic dissection showed a similar tendency, whereas thoracic aortic aneurysm showed no significant differences.ConclusionsThe defect area formed when using a needle holder tended to be smaller than that when using forceps, especially in acute aortic dissection. When performing anastomotic pullouts in fragile aortic walls, using a needle holder may help reduce bleeding and prevent distal anastomotic new entry tears.

Authors

Institutions

Publication Details

Journal
Asian Cardiovascular and Thoracic Annals
Published
2026-02-27
DOI
https://doi.org/10.1177/02184923261425704
Primary Topic
Hemostasis and retained surgical items
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aortic wall needle extraction: Difference between forceps and needle holder use

Hideichi Wada, Masato Furui, Ryo Ozuru, Yuta Sukehiro et al.
Asian Cardiovascular and Thoracic Annals
Hemostasis and retained surgical items
article

Aortic wall needle extraction: Difference between forceps and needle holder use

Hideichi Wada, Masato Furui, Ryo Ozuru, Yuta Sukehiro, Mikiko Aoki, Go Kuwahara
article en

Abstract

BackgroundWe investigated the difference in the extracted surfaces between extractions carried out using forceps and a needle holder, focusing on needle extraction manipulation for smaller needle-hole defects.MethodsIn this prospective observational study, we included patients who underwent aortic surgery at our Hospital between December 2023 and January 2025. Aortic wall samples were collected from the patients with acute type A aortic dissection (<i>n = </i>20) and thoracic aortic aneurysm (<i>n = </i>20). Two hundred needle holes were created in the samples from each disease type and randomized into two groups: the forceps (<i>n = </i>100) and needle holder (<i>n = </i>100) groups. The long axis, short axis, and area of needle-hole defects were measured and compared between the two groups.ResultsOverall, the long axis in the needle holder group was significantly shorter than that in the forceps group (forceps: 0.52 ± 0.18 vs. needle holder: 0.48 ± 0.12 mm, <i>P</i> = 0.036). The short axis was not significantly different between the groups (forceps: 0.26 ± 0.07 vs. needle holder: 0.25 ± 0.06 mm, <i>P</i> = 0.223). The defect area in the needle holder group was significantly smaller than that in the forceps group (forceps: 0.11 ± 0.06 vs. needle holder: 0.09 ± 0.03 mm2, <i>P</i> = 0.022). Acute aortic dissection showed a similar tendency, whereas thoracic aortic aneurysm showed no significant differences.ConclusionsThe defect area formed when using a needle holder tended to be smaller than that when using forceps, especially in acute aortic dissection. When performing anastomotic pullouts in fragile aortic walls, using a needle holder may help reduce bleeding and prevent distal anastomotic new entry tears.

Asian Cardiovascular and Thoracic AnnalsVol. 34(3)
Fukuoka University (JP), Fukuoka University Hospital (JP)
Openalex Percentile: Top 41%
Hemostasis and retained surgical items
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.