Performance evaluation of an ejector-enhanced modified cascade–auto-cascade refrigeration system for ultra-low-temperature cooling

Auto-cascade refrigeration (ACR) systems can reach ultra-low temperatures but often suffer from two major drawbacks: high compressor exit (discharge) temperatures and low system performance. Many previous studies have focused on performance enhancement while neglecting the critical issue of compressor discharge temperature. Although techniques such as vapor injection, two-stage compression, and additional heat exchangers can enhance system efficiency, they also introduce structural complexity and higher costs. To address these challenges, this study proposes a novel hybrid refrigeration cycle that integrates a cascade cycle with an ACR system. The objective is to lower the compressor discharge temperature and improve the overall performance while maintaining simplicity through the use of environmentally friendly refrigerant mixtures. Four different configurations were studied: three modified cascade refrigeration cycles and one ejector-enhanced cascade refrigeration (MECR) cycle. The MECR system achieved the best results, with a coefficient of performance of 0.894 and an exergy efficiency of 30.1% at evaporator exit and condensation temperatures of −60 °C and 30 °C, respectively. The compressor discharge temperature was reduced by 36.9%, improving safety when using low-global warming potential refrigerants. Relative to comparable systems reported in the literature, the proposed design improved exergy efficiency by up to 58.2% without compromising structural simplicity. These findings demonstrate that the MECR configuration provides a practical balance between performance improvement, safety, and system simplicity, offering meaningful advantages for ultra-low-temperature applications without increasing the system complexity.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Published
2026-02-27
DOI
https://doi.org/10.1177/09544089261424171
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of an ejector-enhanced modified cascade–auto-cascade refrigeration system for ultra-low-temperature cooling

Lutfiye Altay, Ibrahim Karacayli, Arif Hepbasli
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Refrigeration and Air Conditioning Technologies
article

Performance evaluation of an ejector-enhanced modified cascade–auto-cascade refrigeration system for ultra-low-temperature cooling

Lutfiye Altay, Ibrahim Karacayli, Arif Hepbasli
article en

Abstract

Auto-cascade refrigeration (ACR) systems can reach ultra-low temperatures but often suffer from two major drawbacks: high compressor exit (discharge) temperatures and low system performance. Many previous studies have focused on performance enhancement while neglecting the critical issue of compressor discharge temperature. Although techniques such as vapor injection, two-stage compression, and additional heat exchangers can enhance system efficiency, they also introduce structural complexity and higher costs. To address these challenges, this study proposes a novel hybrid refrigeration cycle that integrates a cascade cycle with an ACR system. The objective is to lower the compressor discharge temperature and improve the overall performance while maintaining simplicity through the use of environmentally friendly refrigerant mixtures. Four different configurations were studied: three modified cascade refrigeration cycles and one ejector-enhanced cascade refrigeration (MECR) cycle. The MECR system achieved the best results, with a coefficient of performance of 0.894 and an exergy efficiency of 30.1% at evaporator exit and condensation temperatures of −60 °C and 30 °C, respectively. The compressor discharge temperature was reduced by 36.9%, improving safety when using low-global warming potential refrigerants. Relative to comparable systems reported in the literature, the proposed design improved exergy efficiency by up to 58.2% without compromising structural simplicity. These findings demonstrate that the MECR configuration provides a practical balance between performance improvement, safety, and system simplicity, offering meaningful advantages for ultra-low-temperature applications without increasing the system complexity.

Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Ege University (TR), Yaşar University (TR)
Openalex Percentile: Top 42%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.