Case Report: Failed restoration of left ventricular function after Myosplint® placement followed by successful HeartMate 3™ LVAD implantation.

Abstract Background Mechanical restoration devices such as the Myosplint® were developed in the early 2000s to reshape left ventricular geometry and delay disease progression in patients with dilated cardiomyopathy. Despite initial safety and feasibility, long-term clinical efficacy remained limited. Today, patients with prior Myosplint® implantation may still present with end-stage heart failure requiring long-term mechanical circulatory support. However, device removal during HeartMate 3™ LVAD implantation may pose technical challenges due to altered myocardial anatomy. Case Summary We report the case of a 65-year-old male with combined dilated and ischemic cardiomyopathy and severe mitral valve regurgitation who had received two Myosplint® devices and mitral valve annuloplasty in 2001. After progressive decline in cardiac function, HeartMate 3™ LVAD implantation was indicated. During surgery, the Myosplint® tendons were clearly visible through the apical coring site and were transected close to their insertion points without complication. The epicardial buttons were left in situ. Mitral valve replacement was not performed, as significant reduction in regurgitation was expected through adequate LV unloading alone. Postoperative recovery was uneventful, and follow-up echocardiography confirmed only mild residual mitral insufficiency. Discussion Our case highlights a safe and straightforward technique for Myosplint® tendon management during HeartMate 3™ LVAD implantation. It also supports a conservative approach to mitral valve intervention in select cases, suggesting that adequate LV unloading alone may suffice to reduce regurgitation. This experience provides guidance for surgeons managing patients with prior mechanical restoration devices undergoing LVAD implantation.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Case Reports
Published
2026-02-25
DOI
https://doi.org/10.1093/ehjcr/ytag088
Primary Topic
Cardiac Structural Anomalies and Repair
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case Report: Failed restoration of left ventricular function after Myosplint® placement followed by successful HeartMate 3™ LVAD implantation.

Philipp Schnackenburg, Gerd Juchem, Christian Hagl, Christine Kamla et al.
European Heart Journal - Case Reports
Cardiac Structural Anomalies and Repair
article

Case Report: Failed restoration of left ventricular function after Myosplint® placement followed by successful HeartMate 3™ LVAD implantation.

Philipp Schnackenburg, Gerd Juchem, Christian Hagl, Christine Kamla, Christoph Mueller
article en

Abstract

Abstract Background Mechanical restoration devices such as the Myosplint® were developed in the early 2000s to reshape left ventricular geometry and delay disease progression in patients with dilated cardiomyopathy. Despite initial safety and feasibility, long-term clinical efficacy remained limited. Today, patients with prior Myosplint® implantation may still present with end-stage heart failure requiring long-term mechanical circulatory support. However, device removal during HeartMate 3™ LVAD implantation may pose technical challenges due to altered myocardial anatomy. Case Summary We report the case of a 65-year-old male with combined dilated and ischemic cardiomyopathy and severe mitral valve regurgitation who had received two Myosplint® devices and mitral valve annuloplasty in 2001. After progressive decline in cardiac function, HeartMate 3™ LVAD implantation was indicated. During surgery, the Myosplint® tendons were clearly visible through the apical coring site and were transected close to their insertion points without complication. The epicardial buttons were left in situ. Mitral valve replacement was not performed, as significant reduction in regurgitation was expected through adequate LV unloading alone. Postoperative recovery was uneventful, and follow-up echocardiography confirmed only mild residual mitral insufficiency. Discussion Our case highlights a safe and straightforward technique for Myosplint® tendon management during HeartMate 3™ LVAD implantation. It also supports a conservative approach to mitral valve intervention in select cases, suggesting that adequate LV unloading alone may suffice to reduce regurgitation. This experience provides guidance for surgeons managing patients with prior mechanical restoration devices undergoing LVAD implantation.

European Heart Journal - Case Reports
LMU Klinikum (DE), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 42%
Cardiac Structural Anomalies and Repair
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.