Continuous Accelerometry-Based Tremor Detection During Daily Living

As a step towards advancing adaptive DBS control for Parkinson's disease, we have developed an automated algorithm that detects tremor continuously on a seconds-resolution time scale from a wearable accelerometer and present the feasibility study test results. Triaxial acceleration data were wirelessly streamed from an Apple Watch as well as acquired from an internal accelerometer in the implanted DBS device itself. The algorithm first determines if there is any high-power voluntary activity, such as walking, using the arm, or transitioning from sitting to standing; then, it identifies peaks in the 4-7 Hz Parkinsonian tremor frequency band. Peak detection for tremor activity was more accurate using the Apple Watch than the IPG. Peak and harmonic detection were also more accurate using continuous wavelet transforms than short-time Fourier transform. According to the repeated measures correlation, our detection algorithm correlated strongly with DBS intensity (Subject RZCH: r = -0.93, <i>p</i> = 3.6 × 10<sup>-5</sup>; 6KOZ: r = -0.97, <i>p</i> = 1.6 × 10<sup>-5</sup>, NU5U: r = -0.94, <i>p</i> = 0.057). Pearson's correlation coefficient between our tremor detection algorithm and the currently accepted industry metric was found to be 0.57 (t-value = 8.5, dof = 148, <i>p</i> < 1 × 10<sup>-6</sup>). Our algorithm is distinctive in the capability to detect Parkinsonian tremor, with a high degree of clinical relevance, during daily living activities and is able to discriminate tremor from walking, using a convenient, commercial wrist-worn accelerometer.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-26
DOI
https://doi.org/10.3390/s26051459
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Accelerometry-Based Tremor Detection During Daily Living

Stephen L. Schmidt, Deborah Won, Rocio Rodriguez Capilla, Arabo Gholian et al.
Sensors
Neurological disorders and treatments
article

Continuous Accelerometry-Based Tremor Detection During Daily Living

Stephen L. Schmidt, Deborah Won, Rocio Rodriguez Capilla, Arabo Gholian, Orlando Martinez, Luis Martinez, Hector Gardea, Dennis A. Turner
article en

Abstract

As a step towards advancing adaptive DBS control for Parkinson's disease, we have developed an automated algorithm that detects tremor continuously on a seconds-resolution time scale from a wearable accelerometer and present the feasibility study test results. Triaxial acceleration data were wirelessly streamed from an Apple Watch as well as acquired from an internal accelerometer in the implanted DBS device itself. The algorithm first determines if there is any high-power voluntary activity, such as walking, using the arm, or transitioning from sitting to standing; then, it identifies peaks in the 4-7 Hz Parkinsonian tremor frequency band. Peak detection for tremor activity was more accurate using the Apple Watch than the IPG. Peak and harmonic detection were also more accurate using continuous wavelet transforms than short-time Fourier transform. According to the repeated measures correlation, our detection algorithm correlated strongly with DBS intensity (Subject RZCH: r = -0.93, <i>p</i> = 3.6 × 10<sup>-5</sup>; 6KOZ: r = -0.97, <i>p</i> = 1.6 × 10<sup>-5</sup>, NU5U: r = -0.94, <i>p</i> = 0.057). Pearson's correlation coefficient between our tremor detection algorithm and the currently accepted industry metric was found to be 0.57 (t-value = 8.5, dof = 148, <i>p</i> < 1 × 10<sup>-6</sup>). Our algorithm is distinctive in the capability to detect Parkinsonian tremor, with a high degree of clinical relevance, during daily living activities and is able to discriminate tremor from walking, using a convenient, commercial wrist-worn accelerometer.

SensorsVol. 26(5)
Duke University (US), California State University Los Angeles (US), Duke Medical Center (US), Duke University Hospital (US)
California State University
Reduced inequalities
Openalex Percentile: Top 46%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.